Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T03CM03753
Permit Details
Apply Date:
07/29/2003
Applicant:
STEVE KATTNER/CHARLY PATEL
Description:
NEW:DRUG STORE
Contractors:
- HAWORTH CORP
Permit Reviews
Permit Number - T03CM03753
Permit Status: C of o
Permit Description: NEW:DRUG STORE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/02/2004 | RESUBMITTAL | 04/12/2004 | COMPLETED |
04/02/2004 | SITE | 05/05/2004 | COMPLETED |
04/12/2004 | RESUBMITTAL | 05/05/2004 | COMPLETED |
04/21/2005 | 3RD PARTY REVIEW-REVISION/OTHER | 04/22/2005 | COMPLETED |
04/22/2005 | POST 3RD PARTY REVIEW | 04/22/2005 | COMPLETED |
06/09/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 06/09/2004 | COMPLETED |
07/29/2003 | PLANS OK TO SUBMIT - 3RD PARTY | 07/29/2003 | COMPLETED |
07/30/2003 | 3RD PARTY REVIEW-COMMERCIAL | 08/20/2003 | COMPLETED |
09/02/2003 | 3RD PARTY REVIEW-COMMERCIAL | 10/30/2003 | COMPLETED |
12/05/2003 | RESUBMITTAL | 02/12/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM03753
Permit Status: C of o
Permit Description: NEW:DRUG STORE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/29/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM03753
Permit Description: NEW:DRUG STORE
Total Completed Inspections - 42
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/26/2004 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection :* |
06/03/2004 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :*/ FROM 2-WAY C.O. AIR TEST 6 PSI UNDERGROUND AND THREE 2" VENTS TO 13' ON NORTH IN WALL. ONE 2" VENT SOUTH EAST CORNER IN WALL OK. ALL FLOOR SINKS WILL REQUIRE CLEAN OUTS AT INTERMEDIATE. 1½ H2O STUBBED UP AND OUT APP. 5' AIR TEST OK. NE CORNER. |
06/17/2004 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection :* |
07/08/2004 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :*/ 1) WASTE AND VENT AIR TEST 6 PSI THRU ROOF OK 2) NEED TO SEE ROOF FLASHINGS 3) CLOSET FLANGES OK |
07/08/2004 | FRAMING | LHANLY | Approved | IVRS - Inspection :*INTERIOR DONE - SOFFITS AND HANGING WALL OUTSIDE ARE INCOMPLETE. |
07/12/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
07/12/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :*/ 1) TRAPEZE UNDER DROPS (VERTICAL) SUPPLY ON LARGE UNITS 2) DUCTS ABOVE RESTROOMS OK |
07/14/2004 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection :* |
07/22/2004 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection :*/ 1) ABOVE CEILING IS OK FOR GRID AND TILE |
07/26/2004 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
07/30/2004 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :*/ 1) OK FOR CEILING TILES |
08/03/2004 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
08/06/2004 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection :* |
08/06/2004 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection :* |
08/06/2004 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection :* |
08/06/2004 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection :* |
08/06/2004 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :* |
08/06/2004 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection :* |
08/06/2004 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection :* |
08/06/2004 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :* |
09/16/2004 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :*/CORRECTION MADE |
10/14/2004 | FIRE - HYDRANTS | LTHOMAS | Approved | STILL NEED SPRINKLER FINAL |
10/18/2004 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :*/INSPECTED ON 7/8/04 APPROVED ENTERED10/18/04 |
10/20/2004 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection :* |
10/20/2004 | ELECTRIC - UNDERGROUND | JORTA | Approved | IVRS - Inspection :* |
10/27/2004 | ELECTRIC - CABLE DROP | RSUBA | Approved | IVRS - Inspection :* |
10/28/2004 | TEP CLEARANCE - AM | TACHONG | Approved | CLEAR CEC |
11/09/2004 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :*/OK TEMP POWER FOR TESTING |
11/09/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :*/OK FOR TEMP POWER FOR TESTING |
11/10/2004 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection :*/ 1) APPROVED FOR TEMP POWER ?, TEST AND SECURITY-CLEARANCE SUBJECT TO BOND |
11/10/2004 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
11/24/2004 | TEP CLEARANCE - PM | JKOZUCH | Approved | ECO PER BETH GRANT |
12/28/2004 | FIRE - FINAL | LTHOMAS | Approved | OK FOR FINAL C OF O |
12/28/2004 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
12/28/2004 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
12/28/2004 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
06/29/2005 | ENGINEERING - FINAL | JSALINE | Approved | C OF O APPROVED. |
06/29/2005 | ENGINEERING - FINAL | JSALINE | Approved | |
06/30/2005 | NPPO - FINAL | ACONNOR | Approved | |
06/30/2005 | LANDSCAPE - FINAL | ACONNOR | Approved | |
07/11/2005 | SIGN - FINAL | CSTEPHEN | Approved | OK FOR TEMPORARY C OF O |
08/14/2007 | RIGHT OF WAY - FINAL | DLEE | Approved | PER PHONE CALL |