Permit: T03CM03753

Parcel: 13610023L


Addresses:

2601 S HOUGHTON RD

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
06/01/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
05/25/2005 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) CAP OF DEMO FLOOR SINK IN PHOTO AREA OK
2) CAP OF 1/2" H20 IN WALL ? AREA OK
3) CAP OFF TRAP PRIMER TO ? FLOOR SINK IN WALL ? AREA. REVISED CITY APPROVED PLAN ON SITE
06/03/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/ FROM 2-WAY C.O. AIR TEST 6 PSI UNDERGROUND AND THREE 2" VENTS TO 13' ON NORTH IN WALL. ONE 2" VENT SOUTH EAST CORNER IN WALL OK. ALL FLOOR SINKS WILL REQUIRE CLEAN OUTS AT INTERMEDIATE. 1½ H2O STUBBED UP AND OUT APP. 5' AIR TEST OK. NE CORNER.