Permit: T03CM02901
Permit Details
Status:
Final
Type:
MULTI FAMILY NEW
Address:
3722 N MOUNTAIN AV #01
Address NEW:
3722 N MOUNTAIN AV #01
Apply Date:
06/13/2003
Applicant:
W S SCHAGEL CONSTRUCTION
Description:
NEW:TRIPLEX
Architects:
- BURTON, RICHARD ROGHAAR
Contractors:
- WILLIAM S SCHAEGEL CONSTR
Permit Reviews
Permit Number - T03CM02901
Permit Status: Final
Permit Description: NEW:TRIPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/14/2004 | COMMERCIAL NEW | 03/19/2004 | COMPLETED |
| 01/14/2004 | SITE | 04/28/2004 | COMPLETED |
| 03/19/2004 | COMMERCIAL NEW | 04/28/2004 | COMPLETED |
| 04/28/2004 | RESUBMITTAL | 08/19/2004 | COMPLETED |
| 06/13/2003 | PLANS OK TO SUBMIT - COMM | 08/28/2003 | COMPLETED |
| 06/13/2003 | PLANS OK TO SUBMIT - SITE | 08/28/2003 | COMPLETED |
| 08/28/2003 | COMMERCIAL NEW | 10/06/2003 | COMPLETED |
| 08/28/2003 | SITE | 10/06/2003 | COMPLETED |
| 11/22/2004 | REVISION - WALK THRU | 11/22/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM02901
Permit Status: Final
Permit Description: NEW:TRIPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/13/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM02901
Permit Description: NEW:TRIPLEX
Total Completed Inspections - 29
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/21/2004 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | IVRS - Inspection :* 1 1/2" & 1" PUC CONDUITS FROM SERVICE POINT TO EACH UNIT OK TO COVER |
| 09/21/2004 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :*1) ABS INSTALLED IN LIEN OF PVC. PROVIDE LETTER FROM ARCHITECT APPROVING ABS. 2) ABS SWV UNDERGROUND OK. 3) ABS SWER FROM 2 WAY TO TIE IN AT EXISTING . OK WATER TEST OK 4) YARD WATER FROM EXISISTING TO THREE RISERS AT BLDG OK. OK TO COVER. 5) CONTRACTOR TO INSURE CLEAN FILL AT COPPER. |
| 09/21/2004 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :*1) ABS INSTALLED IN LIEN OF PVC. PROVIDE LETTER FROM ARCHITECT APPROVING ABS. 2) ABS SWV UNDERGROUND OK. 3) ABS SWER FROM 2 WAY TO TIE IN AT EXISTING . OK WATER TEST OK 4) YARD WATER FROM EXISISTING TO THREE RISERS AT BLDG OK. OK TO COVER. 5) CONTRACTOR TO INSURE CLEAN FILL AT COPPER. |
| 09/21/2004 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1) ABS INSTALLED IN LIEN OF PVC. PROVIDE LETTER FROM ARCHITECT APPROVING ABS. 2) ABS SWV UNDERGROUND OK. 3) ABS SWER FROM 2 WAY TO TIE IN AT EXISTING . OK WATER TEST OK 4) YARD WATER FROM EXISISTING TO THREE RISERS AT BLDG OK. OK TO COVER. 5) CONTRACTOR TO INSURE CLEAN FILL AT COPPER. |
| 09/30/2004 | EXCAVATION/LAYOUT REBAR & ZON | HLEYVA | Approved | IVRS - Inspection :* |
| 09/30/2004 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :*APPROVED. 1/0 COPPER UFER TO REBAR. |
| 10/06/2004 | BUILDING PRE-SLAB | HLEYVA | Approved | IVRS - Inspection :* |
| 11/14/2004 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/14/2004 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/24/2004 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | IVRS - Inspection :$OK TO CLEAR TS UNIT 3 ONLY NBR |
| 11/24/2004 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/24/2004 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection :* |
| 11/26/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO UNIT 3 PER INSPECTOR NO BOND REQUIRED |
| 12/09/2004 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/09/2004 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection :* |
| 12/09/2004 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection :* |
| 12/10/2004 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :*/1)ABS DWV THRU ROOF OK. COPPER WATER OK. TUBS OK. CLOSET FLANGES OK. OK TO COVER ALL AREAS |
| 12/10/2004 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
| 12/13/2004 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/13/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 12/17/2004 | STUCCO MESH | BSTEVENS | Approved | IVRS - Inspection :* |
| 12/22/2004 | SHEET ROCK NAILING | HLEYVA | Approved | IVRS - Inspection :* |
| 02/24/2005 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* |
| 03/02/2005 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* APPROVED |
| 03/02/2005 | NPPO - FINAL | ACONNOR | Approved | |
| 03/02/2005 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 03/11/2005 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* APPROVED |
| 03/11/2005 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1) PLUMBING FINAL OK 2) OK FOR C OF O PENDING ANY OTHER INSPECTION |
| 09/15/2005 | PERMIT FINALED | LJACKSON | Approved |