Permit: T03CM02808
Permit Details
Apply Date:
06/09/2003
Applicant:
MATT CLARK
Description:
TI:RESTAURANT
Architects:
- PLEGER, TIMOTHY GEORGE
Contractors:
- CANOPUS CONSTRUCTION ,
Permit Reviews
Permit Number - T03CM02808
Permit Status: C of o
Permit Description: TI:RESTAURANT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/09/2003 | PLANS OK TO SUBMIT - COMM | 06/09/2003 | COMPLETED |
06/09/2003 | COMMERCIAL TI | 07/14/2003 | COMPLETED |
08/11/2003 | RESUBMITTAL | 09/12/2003 | COMPLETED |
09/16/2003 | RESUBMITTAL | 10/27/2003 | COMPLETED |
10/27/2003 | RESUBMITTAL | 11/03/2003 | COMPLETED |
12/12/2003 | REVISION | 01/20/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM02808
Permit Status: C of o
Permit Description: TI:RESTAURANT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/09/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM02808
Permit Description: TI:RESTAURANT
Total Completed Inspections - 29
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/03/2003 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | |
12/08/2003 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection 0000*/ 1) IN WALL AND OVERHEAD H2O PIPING WATER TEST OK EXCEPT FOR BOILER AND TRIM FOR HOT WTR RETURN. 2) WASTE AND VENT IN WALL WTR TEST THRU ROOF OK, EXCEPT REVISED CITY APPROVED DRAWING REQUIRED FOR CHANGES TO OVERHEAD VENTING OR INSTALL PER PLAN. 3) WILL NEED TO SEE CLOSET FLANGES, CONNECTION FOR FLOOR SINKS AND H20 UNDERSLAB. |
12/09/2003 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection 0000*/ 1) INSTALLATION OF CLOSET ?, FLOOR DRAINS, FLOOR SINKS, TRENCH DRAIN AND PRIMER LINES OK FOR LOCATION. 1/2" WATER TO CHEF'S COUNTER OK FOR CONCRETE |
12/09/2003 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) OK 3-1", 4-3/4" PVC CONDUITS IN FORMS 2) OK WALLS EXCEPT AT DIMMING PANEL "L" |
12/15/2003 | FRAMING | RSUBA | Approved | IVRS - Inspection 0000* OK TO SHEET ROCK AS NOTED. (NEED TO SEE THE 1 HR DEMISING WALL REPAIRED PRIOR TO SHEET ROCKING BOTTOM OF SOFFITS). |
12/17/2003 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection 0000*/ INSPECTED DUCT IN SOFFETTS. OK FOR SHEET ROCK. |
12/17/2003 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* |
12/17/2003 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) OK HARD CEILINGS AND SOFFITS |
12/22/2003 | SHEET ROCK NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
12/29/2003 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection 0000*/ INSPECTION ON GREASE DUCTS. OK TO FIRE WRAP. BE SURE TO EXTEND WRAP ALL THE WAY TO TOP OF DUCT AS PER 2000 IMC. IF LANDING IS DIFFICULT AT TOP TAPERED SECTION. USE PINS AS PER MANUFACTURERS INSTRUCTIONS. |
01/16/2004 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000* |
01/27/2004 | PLUMBING - PROGRESS | JSTANLEY | Approved | IVRS - Inspection 0000* |
02/05/2004 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | IVRS - Inspection 0000* |
02/05/2004 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | IVRS - Inspection 0000* |
02/05/2004 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | IVRS - Inspection 0000*/ 1) NEEDS PERMIT FOR T.I. SUITE 151 |
02/06/2004 | FIRE SPKLR - FINAL | JEGAN | Approved | IVRS - Inspection 0000*/ 1) NEED HOOD SYSTEM FINAL FOR C OF O |
02/09/2004 | FIRE - FINAL | LTHOMAS | Approved | IVRS - Inspection 0000* |
02/09/2004 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | IVRS - Inspection 0000*/ 1) OK C OF O |
02/10/2004 | ENGINEERING - FINAL | DROBERTS | Approved | |
02/11/2004 | HEALTH DEPT - FINAL 724-7908 | DTHOMAS | Approved | |
02/11/2004 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000*/ PLEASE PROVIDE TESTING ON BACKFLOW DEVISE FOR COFFEE MAKER. |
02/11/2004 | PLUMBING - GAS PRESS TEST FNL | JSTANLEY | Approved | |
02/11/2004 | PLUMBING - ABOVE CEILING | JSTANLEY | Approved | |
02/12/2004 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*/ ALL CORRECTIONS HAVE BEEN MADE. OK FOR FINAL C OF O. |
02/12/2004 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000* |
02/12/2004 | BUILDING - FINAL | RSUBA | Approved | IVRS - Inspection 0000* |
02/20/2004 | PERMIT FINALED | PWHIDDON | Approved | |
02/20/2004 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
02/20/2004 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |