Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T03CM01662
Permit Details
Apply Date:
04/04/2003
Applicant:
ROBINETTE ARCHITECTS
Description:
TI: CAFE
Contractors:
- SAVARI L L C
Permit Reviews
Permit Number - T03CM01662
Permit Status: C of o
Permit Description: TI: CAFE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/04/2003 | PLANS OK TO SUBMIT - 3RD PARTY | 04/04/2003 | COMPLETED |
04/04/2003 | 3RD PARTY REVIEW-COMMERCIAL TI | 04/23/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM01662
Permit Status: C of o
Permit Description: TI: CAFE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/04/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM01662
Permit Description: TI: CAFE
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/27/2003 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*/ 1) FINAL CONNECTION TO EXISTING-OK 2) OK TO COVER ALL AREAS |
06/20/2003 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
06/26/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | 1) ABS DWV THRU ROOF OK WATER TEST OK. 2) COPPER OVERHEAD AND IN THE WALLS OK PRESSURE TEST OK. 3) NEED TO SEE COPPER IN MECH ROOM. 4) NEED TO SEE CLOSET FLANGES. 5) OK TO COVER. |
07/03/2003 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
07/14/2003 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000*/ 1) TWO 2" YARDWATER PIPING FROM METER THRU RPPBP'S AND CONNECTED AT BLDG OK, PRESSURE TEST OK, TRANSITION FITTINGS OK, SILL FUSED JOINTS OK 2) OK TO COVER |
07/23/2003 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000*/ GAS PRESSURE TEST OK. |
10/10/2003 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection 0000* |
10/10/2003 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection 0000* |
10/27/2003 | ELECTRIC - FINAL | MCAPISTR | Approved | SENT TO TEP ON 11/25PM |
10/27/2003 | ELECTRIC - CONSTRUCTION POWER | MCAPISTR | Approved | |
10/27/2003 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
10/27/2003 | FRAMING | AQUIROZ | Approved | IVRS - Inspection 0000* |
10/27/2003 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
11/03/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
11/06/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
11/06/2003 | MECHANICAL - HOOD SYSTEMS | CWILLIAM | Approved | |
11/06/2003 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
11/24/2003 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*/ 1) CORRECTIONS MADE OK. 2) OK FOR C OF O PENDING ANY OTHER INSP. 3) LAST INSPECTOR TO LEACE GAS CARD. |
11/25/2003 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
11/28/2003 | BUILDING - FINAL | RSUBA | Approved | IVRS - Inspection 0000* |
12/05/2003 | SIGN - FINAL | DJOHNSTO | Approved | IVRS - Inspection 0000* |
12/23/2003 | HEALTH DEPT - FINAL 724-7908 | SBROWNIN | Approved | |
01/06/2004 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
01/06/2004 | FIRE - KITCHEN EXH HOOD FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
01/27/2004 | ENGINEERING - FINAL | DROBERTS | Approved | |
01/28/2004 | PERMIT FINALED | HLEYVA | Approved |