Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
02/21/2003
Applicant:
CONTRAVEST PROPERTIES
Description:
SFR:TD#15-07-02
Contractors:
  • CONTRAVEST PROPERTIES

Permit Reviews

Permit Number - T03CM00931
Permit Status: C of o
Permit Description: SFR:TD#15-07-02
Start Date Submittal Complete Date Status  
02/21/2003 RESIDENTIAL BLDG/ZONING/FLOOD-WALK THRU 03/25/2003 COMPLETED Review Details
10/14/2003 REVISION 10/14/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM00931
Permit Status: C of o
Permit Description: SFR:TD#15-07-02
Total Outstanding Activity Conditions - 1
Date Name
02/21/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM00931
Permit Description: SFR:TD#15-07-02
Total Completed Inspections - 23
Date Description Inspector Results Comments
04/24/2003 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection 0000*
04/24/2003 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection 0000*
04/24/2003 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000*/ 1) NOTE: PLOT CALLS FOR 6' TO PROPERTY LINE, YOU HAVE 5'-8". REVISE PLOT FOR NEXT INSPECTION. PRE SLAB/LAYOUT ALSO PROPERTY LINE AT GARAGE 6" TO PROPERTY LINE THAT'S FROM FINISH WALL. PLEASE PUT STRING LINE UP AT EAST PROPERTY LINE
05/05/2003 BUILDING PRE-SLAB HPEDROZA Approved IVRS - Inspection 0000*
05/05/2003 EXCAVATION/LAYOUT REBAR & ZON HPEDROZA Approved IVRS - Inspection 0000*
05/08/2003 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection 0000*
06/18/2003 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*/1) #2 SHEAR WALL GETS BLKS AT 4'8", YOU NEED ANOTHER ROW FOR THE UPPER JOINT IF USING 4' WIDE SHEETS; 2) SW4 SHEAR NAIL SPACING IS 4" O.C. EDGES, 12" IN FIELD; 3) PLAN CALLS FOR EXT WALL, B/PLATES TO BE ANCHORED WITH EMBED BOLTS NOT EXPANSION TYPE; 4) PLAN DOES EXPLAIN SHEAR TRANSFERS; 5) WIND BRACES TO GO TO ROOF DECK; 6) NEED TRUSS SHOP DRAWINGS ON SITE; 7) MARKED ON ROOF S/E/ WEST QUAD. IN BLACK MISSED NAILING; 8) #2.5 AT EA STUD PER DETAIL END TRUSS TO WALL NON-BEARING; INSPECTION FOR GARAGE AND MAIN HOUSE
07/28/2003 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection 0000*SENT TO TEP ON 7/29AM
07/28/2003 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection 0000*SENT TO TEP ON 7/29AM
09/17/2003 STUCCO MESH RFREIDIN Approved IVRS - Inspection 0000*
10/06/2003 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
10/06/2003 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection 0000*
10/06/2003 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
10/06/2003 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
10/06/2003 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*
10/06/2003 FRAMING RFREIDIN Approved IVRS - Inspection 0000*
10/06/2003 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*
03/01/2004 PERMIT FINALED RFREIDIN Approved
03/01/2004 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/01/2004 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/01/2004 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection 0000* SENT TO TEP ON 03/02/04AM
03/01/2004 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/01/2004 U VALUE FOR WINDOW RFREIDIN Approved

Documents

File Name Document Type  
None CERT OF OCC VIEW