Permit: T03CM00931
Permit Details
Apply Date:
02/21/2003
Applicant:
CONTRAVEST PROPERTIES
Description:
SFR:TD#15-07-02
Contractors:
- CONTRAVEST PROPERTIES
Permit Reviews
Permit Number - T03CM00931
Permit Status: C of o
Permit Description: SFR:TD#15-07-02
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/21/2003 | RESIDENTIAL BLDG/ZONING/FLOOD-WALK THRU | 03/25/2003 | COMPLETED |
10/14/2003 | REVISION | 10/14/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM00931
Permit Status: C of o
Permit Description: SFR:TD#15-07-02
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/21/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM00931
Permit Description: SFR:TD#15-07-02
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/24/2003 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection 0000* |
04/24/2003 | PLUMBING - YARD WTR LINE/TEST | RFREIDIN | Approved | IVRS - Inspection 0000* |
04/24/2003 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) NOTE: PLOT CALLS FOR 6' TO PROPERTY LINE, YOU HAVE 5'-8". REVISE PLOT FOR NEXT INSPECTION. PRE SLAB/LAYOUT ALSO PROPERTY LINE AT GARAGE 6" TO PROPERTY LINE THAT'S FROM FINISH WALL. PLEASE PUT STRING LINE UP AT EAST PROPERTY LINE |
05/05/2003 | BUILDING PRE-SLAB | HPEDROZA | Approved | IVRS - Inspection 0000* |
05/05/2003 | EXCAVATION/LAYOUT REBAR & ZON | HPEDROZA | Approved | IVRS - Inspection 0000* |
05/08/2003 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection 0000* |
06/18/2003 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection 0000*/1) #2 SHEAR WALL GETS BLKS AT 4'8", YOU NEED ANOTHER ROW FOR THE UPPER JOINT IF USING 4' WIDE SHEETS; 2) SW4 SHEAR NAIL SPACING IS 4" O.C. EDGES, 12" IN FIELD; 3) PLAN CALLS FOR EXT WALL, B/PLATES TO BE ANCHORED WITH EMBED BOLTS NOT EXPANSION TYPE; 4) PLAN DOES EXPLAIN SHEAR TRANSFERS; 5) WIND BRACES TO GO TO ROOF DECK; 6) NEED TRUSS SHOP DRAWINGS ON SITE; 7) MARKED ON ROOF S/E/ WEST QUAD. IN BLACK MISSED NAILING; 8) #2.5 AT EA STUD PER DETAIL END TRUSS TO WALL NON-BEARING; INSPECTION FOR GARAGE AND MAIN HOUSE |
07/28/2003 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection 0000*SENT TO TEP ON 7/29AM |
07/28/2003 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection 0000*SENT TO TEP ON 7/29AM |
09/17/2003 | STUCCO MESH | RFREIDIN | Approved | IVRS - Inspection 0000* |
10/06/2003 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
10/06/2003 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | IVRS - Inspection 0000* |
10/06/2003 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
10/06/2003 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
10/06/2003 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
10/06/2003 | FRAMING | RFREIDIN | Approved | IVRS - Inspection 0000* |
10/06/2003 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection 0000* |
03/01/2004 | PERMIT FINALED | RFREIDIN | Approved | |
03/01/2004 | MECHANICAL - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
03/01/2004 | PLUMBING - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
03/01/2004 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* SENT TO TEP ON 03/02/04AM |
03/01/2004 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
03/01/2004 | U VALUE FOR WINDOW | RFREIDIN | Approved |