Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM00931
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/06/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
07/03/2003 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000* STILL HAVE A.B ISSUE B SHEAR TRANSFER FROM 6-24-03 INSPEC | |
06/24/2003 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000* | |
06/20/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SEE ITEMS ON LAST INSPECTION, YOUR ABOUT 50 PERCENT FINISHED | |
06/18/2003 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*1) ANCHOR BOLTS; PLAN REQS; WET SET; YOU HAVE EXPANSION TYPE. THIS MUST BE APPROVED BY THE ENGINEER OF RECORD. 2) SW2 SJEAR WALL IS A BLOCKED WALL. YOU NEED BLKS AT 4', UNLESS THE DRYWALL IS TO BE INSTALLED VERTICALLY. 3) NO SHEAR TRANSFER DETAIL ON PLAN SW3 INTERIOR SHEAR WALL |