Permit: T03CM00931

Parcel: 141012640


Addresses:

10507 E CERULEAN WY


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM00931

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/06/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
07/03/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000* STILL HAVE A.B ISSUE B SHEAR TRANSFER FROM 6-24-03 INSPEC
06/24/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*
06/20/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) SEE ITEMS ON LAST INSPECTION, YOUR ABOUT 50 PERCENT FINISHED
06/18/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*1) ANCHOR BOLTS; PLAN REQS; WET SET; YOU HAVE EXPANSION TYPE. THIS MUST BE APPROVED BY THE ENGINEER OF RECORD. 2) SW2 SJEAR WALL IS A BLOCKED WALL. YOU NEED BLKS AT 4', UNLESS THE DRYWALL IS TO BE INSTALLED VERTICALLY. 3) NO SHEAR TRANSFER DETAIL ON PLAN SW3 INTERIOR SHEAR WALL