Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM00931
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/06/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
09/25/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) DON'T FORGET ACCESS DOOR/PANEL TO JACUZZI MOTOR 2) EXHAUST FAN DUCT NOT CONNECTED TO ROOF JACK EAST BATH, ALSO WHAT TYPE LIGHT FIXTURE GOES OVER TUB PUT BACKING ALONG THE SIDES OF THE TUB, FOR DRYWALL 3) BLOCK AND SECURE WATER SERVICE FRONT BEDROOM 4) UNSECURED DUCT ABOVE WATER HEATER 5) FROM LAST INSPECTION BANG PLATE ALL ROMEX AND PIPE, PROTECT FROM DRYWALL NAILS 6) MISSING DAMPER IN EAST BATH FAN 7) OSB CUT FOR JACUZZI DRAIN, RE-INSTALL OSB TO SHEAR 8) BLOCK DINING ROOM CEILING DUCT 9) GLENN PLEASE HAVE BOLT INSPECTION STAMPED BY CITY PLAN EXAMINER, STAMPS ON PLAN IS A DIFFERENT/PERSON | |
09/17/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) HOLE IN PEX FROM LATH STAPLE FRONT HOSE BIB 2) PROTECT ALL PIPES AND WIRE FROM DRYWALL NAILS 3) FIRE-BLOCK AT FIREPLACE 4) IN KITCHEN MOVE PEX FROM ABOVE LIGHT CAN 5) STRAP TOP PLATE BOTH SIDE STOVE VENT 6) FULL SIZE BLOCKS AT DIRECT VENT, BOX IN PENETRATION THRU WALL 7) FLOOR PLAN NOT THE SAME AS PLAN 8) PLEASE SUPPLY ENGINEERS OK FOR EXTERIOR A BOLTS |