Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T03CM00514
Permit Details
Apply Date:
01/31/2003
Applicant:
N/A
Description:
TI:RESTAURANT
Contractors:
- COLE ENTERPRISES L L C
Permit Reviews
Permit Number - T03CM00514
Permit Status: Expired
Permit Description: TI:RESTAURANT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/31/2003 | PLANS OK TO SUBMIT - COMM | 01/31/2003 | COMPLETED |
01/31/2003 | 3RD PARTY REVIEW-COMMERCIAL TI | 03/24/2003 | COMPLETED |
02/11/2003 | PLANS OK TO SUBMIT - SITE | 02/11/2003 | COMPLETED |
02/11/2003 | SITE | 03/24/2003 | COMPLETED |
04/11/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 04/16/2007 | COMPLETED |
04/22/2003 | RESUBMITTAL | 05/02/2003 | COMPLETED |
08/06/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 08/10/2004 | COMPLETED |
08/27/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 08/31/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM00514
Permit Status: Expired
Permit Description: TI:RESTAURANT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
01/31/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03CM00514
Permite Description: TI:RESTAURANT
Total Outstanding Inspections - 24
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
BUILDING - FINAL | N/A | Not Inspected | ||
ELECTRIC - UFER | N/A | Not Inspected | ||
ELECTRIC - UNDERGROUND | N/A | Not Inspected | ||
ELECTRIC - TEMPORARY SERVICE | N/A | Not Inspected | ||
MECHANICAL - FINAL | N/A | Not Inspected | ||
FIRE - FINAL | N/A | Not Inspected | ||
HEALTH DEPT - FINAL 724-7908 | N/A | Not Inspected | ||
SIGN - FINAL | N/A | Not Inspected | ||
RIGHT OF WAY - FINAL | N/A | Not Inspected | ||
02/05/2013 | PLUMBING - FINAL | N/A | Not ready for Inspection | NOT READY, RESTAURANT IS FULL OF EQUIPMENT AND SHELVINGS, IT APPEARS THAT NO WORK HAS PROGRESSED SINCE LAST INSPECTION PLEASE CHECK WITH OFFICE ON STATUS OR THIS PERMIT. |
04/08/2013 | BUILDING - PROGRESS | N/A | Partial Approval | |
04/08/2013 | ELECTRIC - PROGRESS | N/A | Partial Approval | |
04/08/2013 | PLUMBING - PROGRESS | N/A | Partial Approval | |
04/08/2013 | MECHANICAL - PROGRESS | N/A | Partial Approval | |
07/12/2004 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) INSTALL MISSING RECEPTACLES 2) INSTALL PLASTER RINGS ON ALL BOXES TO BE SHEET ROCKED 3) MAKE UP ALL GROUND WIRES IN BOXES 4) CEILING OPENINGS TO BE INSTALLED, FINISH J-BOXES IN CEILING |
07/12/2004 | ELECTRIC - ABOVE CEILING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
07/12/2004 | MECHANICAL - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* |
07/12/2004 | MECHANICAL - ABOVE CEILING | N/A | Partial Approval | IVRS - Inspection :* |
08/09/2006 | FIRE - KITCHEN EXH HOOD FINAL | N/A | Denied | NEED A PLAN & PERMIT FOR INSTALL OF HOOD SYSTEM. |
08/17/2010 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MENU BOARD OUTSIDE HAS NOT ELECTRICAL PIPING USED AS CONDUIT (WATER PIPE) 2) 2 SERVICES ON BLDG SAME ADDRESS, GROUND WIRES CUT 3) SIGN OUTSIDE NOT TO CODE 4) PROVIDE LADDER FOR ROOF INSPECTION 5) BOND GEC AND NEUTRAL IN SERVICE DISCONNECT 6) 110V RECEPTS IN KITHEN NEED TO BE GFI PROTECTED PER 210.8 NCER 7) DINING AREA LTG AND FANS NOT ON PLAN 8) ELECTRICAL APPLIANCES TO BE LISTED/MARKED PER 110.3-422 NEC 9) COMPLETE INSPECTION NOT POSSIBLE DUE TO MISC. EQUIP IN WAY |
08/26/2005 | ELECTRIC - CABLE DROP | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CABLE DROP IS APPROVED ONLY ON UNDERGROUND SERVICES 2) JOB NEEDS TO BE FINISHED BEFORE A CLEARANCE FOR CHANGE OVER GIVEN |
08/30/2006 | ENGINEERING - FINAL | N/A | Not ready for Inspection | MET OWNER ON SITE DISCUSSED SITE WORK REQUIRED PER PLAN. |
09/09/2004 | SHEET ROCK NAILING | N/A | Partial Approval | IVRS - Inspection :*/CALL FOR FRAMING OF HOOD SHAFT |
11/24/2008 | MECHANICAL - HOODS | N/A | Partial Approval | IVRS - Inspection :* PROVIDE MAKE UP AIR DUCT |
Completed Inspections
Permit Status: Expired
Permit Number: T03CM00514
Permit Description: TI:RESTAURANT
Total Completed Inspections - 12
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/14/2003 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | MUST HAVE LICENSED PLBG CONTRACTOR DOING THIS WORK. |
10/22/2003 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
10/22/2003 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
10/22/2003 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
03/29/2004 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection :* |
07/09/2004 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
07/09/2004 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
09/02/2004 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :*/APP 1)REVISED PLAN ON SITE 2) OK TO COVER ALL AREAS 3)GAS PRESSURE TEST OK |
09/02/2004 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
09/02/2004 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
09/07/2004 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :*/YARDWATER OK |
09/30/2004 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* 1) GREASE TRAP INSTALLED OK TO COVER |