Permit: T03CM00507
Permit Details
Apply Date:
01/31/2003
Applicant:
TAYLOR, ROBERT JOHN
Description:
TI:OFFICE & MFG TEMP C OF O PER STEVE LONG
Architects:
- TAYLOR, ROBERT JOHN
Contractors:
- TL ROOF AND ASSOCIATES
Permit Reviews
Permit Number - T03CM00507
Permit Status: C of o
Permit Description: TI:OFFICE & MFG TEMP C OF O PER STEVE LONG
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/31/2003 | 3RD PARTY REVIEW-COMMERCIAL TI | 03/07/2003 | COMPLETED |
| 01/31/2003 | PLANS OK TO SUBMIT - COMM | 01/31/2003 | COMPLETED |
| 01/31/2003 | SITE | 03/07/2003 | COMPLETED |
| 04/21/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 04/28/2003 | COMPLETED |
| 04/30/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 05/06/2003 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM00507
Permit Description: TI:OFFICE & MFG TEMP C OF O PER STEVE LONG
Total Completed Inspections - 31
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2003 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) P.O.C. OF NEW BLDG. DRAIN TO EXSISTING BLDG. DRAIN IS OK 3.) OK TO BACKFILL TRENCH. |
| 03/10/2003 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000* |
| 03/27/2003 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
| 03/31/2003 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 03/31/2003 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection 0000* |
| 03/31/2003 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection 0000* |
| 04/01/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000* 1.) ABS DWV THRU ROOF OK 2.) COPPER IN WALLS OK PLEASE ALLOW PLUMBER TIME TO INSULATE HOT LINE BEFORE SHEET ROCK. 3.) CLOSET FLANGES OK 4.) OK TO COVER WALLS. |
| 04/01/2003 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection 0000* |
| 04/03/2003 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection 0000* |
| 04/08/2003 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 04/17/2003 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
| 04/17/2003 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
| 04/22/2003 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR CEILING TILES. |
| 04/22/2003 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*ABOVE CEILING IS OK FOR GRID & TILE. |
| 04/22/2003 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 04/24/2003 | PLUMBING - FINAL | TRINIVJR | Approved | PLBG. FINAL IS OK OK FOR C OF O. |
| 04/28/2003 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000* |
| 05/02/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 05/02/2003 | FIRE SPKLR - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 05/02/2003 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | 1.) ALL CORRECTIONS HAVE BEEN MADE. 2.) OK FOR C OF O. |
| 05/05/2003 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
| 05/05/2003 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | |
| 05/05/2003 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
| 05/05/2003 | SIGN - FINAL | JYBARRA | Approved | NO SIGN AT THIS TIME |
| 05/05/2003 | OUTDOOR LIGHTING FINAL | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 05/05/2003 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000*SENT TO TEP ON 5/6/03 AT 9:15AM OK FOR TEMP C OF O. PENDING VERIFICATION OF BONDING OF BLDG. STEEL, SPRINKLER PIPE, & GAS PIPING TO ELECTRIC SERVICE. |
| 05/06/2003 | LANDSCAPE - FINAL | PGILBERT | Approved | |
| 05/07/2003 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000*WILL CALL T.E.P. |
| 05/07/2003 | ELECTRIC - UNDERGROUND | JORTA | Approved | |
| 05/16/2003 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000*OK C OF O. |
| 08/08/2003 | ENGINEERING - FINAL | JBRUCKME | Approved |