Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address NEW:
2266 S FORGEUS AV
Apply Date:
12/17/2002
Applicant:
MEDINA JOSE LUIS & MEDINA FRANCE
Description:
REMODEL:SFR T02VL01922

Permit Reviews

Permit Number - T02CM05776
Permit Status: Expired
Permit Description: REMODEL:SFR T02VL01922
Start Date Submittal Complete Date Status  
04/18/2003 OTHER 05/22/2003 COMPLETED Review Details
12/17/2002 RESIDENTIAL BLDG/ZONING/FLOOD 04/18/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM05776
Permit Status: Expired
Permit Description: REMODEL:SFR T02VL01922
Total Outstanding Activity Conditions - 1
Date Name
12/17/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02CM05776
Permite Description: REMODEL:SFR T02VL01922
Total Outstanding Inspections - 14
Last Inspection Date Description Inspector Results Comments
REINFORCED MASONRY PRE-GROUT N/A Not Inspected
EXT METAL CLIPS/EXT SHEATHING N/A Not Inspected
ROOF NAILING N/A Not Inspected
PLUMBING - GAS PRESS TEST FNL N/A Not Inspected
02/26/2004 EXCAVATION/LAYOUT REBAR & ZON N/A Denied IVRS - Inspection 0999*/ 1) FOOTING UNDER NORTH CARPORT WALL IS NOT PER 1/2 2) PROVIDE PROOF OF FOOTINGS FOR ENTIRE PROJECT 3) WEST 4 X 8 BEAM MUST BEAR ON AT LEAST 2/3 OF WIDTH 4) GROUND ALL METAL ELECTRIC BOXES ENTIRELY 5) PROVIDE PROOF OF POSTS AND FOOTING AT CARPORT SOUTH WALL 6) BLOCK CARPORT WALL CELLS ARE DIRTY. REMOVE ALL MORTAR AND DEBRIS 7) NO GAS PRESSURE TEST 8) PROVIDE PROOF OF UNDERGROUND PLUMBING INSPECTION OR EXPOSE 9) ELECTRIC JUNCTION BOXES CANNOT TO BE CONSEALED IN CEILING 10) NAIL PROTECT ALL PLUMBING/ELECTRIC WITHIN 1 1/4" OF STUD SURFACE 11) BOND GAS LINE 12) DUCTWORK NOT COMPLETE 13) REVISE PLAN FOR PEX PLUMBING 14) 1/4 AND 2/4 NOT COMPLIED WITH 15) PROVIDE MECHANICAL PLAN
02/26/2004 STEM WALL/RETAINING WALL N/A Denied IVRS - Inspection 0999*
02/26/2004 BUILDING PRE-SLAB N/A Denied IVRS - Inspection 0999*
02/26/2004 FRAMING N/A Denied IVRS - Inspection 0999*/ 1) OK TO DRY WALL HOUSE, CARPORT PENDING
06/24/2004 BUILDING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
06/24/2004 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
06/24/2004 MECHANICAL - FINAL N/A Not ready for Inspection IVRS - Inspection :*
08/10/2004 SHEET ROCK NAILING N/A Partial Approval 1) MAIN HOUSE APPROVED
08/14/2003 PLUMBING - INTERMEDIATE N/A Not ready for Inspection IVRS - Inspection 0000*
11/06/2003 ELECTRIC - FINAL N/A Not ready for Inspection IVRS - Inspection 0000*

Completed Inspections

Permit Status: Expired
Permit Number: T02CM05776
Permit Description: REMODEL:SFR T02VL01922
Total Completed Inspections - 7
Date Description Inspector Results Comments
08/14/2003 PLUMBING - GAS PRESSURE TEST ROHAVER Approved IVRS - Inspection 0000*
10/03/2003 PLUMBING - ROUGH, SOIL ROHAVER Approved IVRS - Inspection 0000*/ 1) COMPLETE TIE-IN TO EXISTING SEWER IN CENTER OF ALLEY WITH APPROVED TRANSITION FITTINGS 2) UNDERSLAB OK TO CLEANOUT EXTERIOR
11/06/2003 ELECTRIC - INTERMEDIATE ROHAVER Approved IVRS - Inspection 0000*/ 1) MUST COMPLETE FRAMING, PLUMBING, GAS, MECHANICAL 2) RECALL PRIOR TO INSULATING OR SHEET ROCKING FOR INSPECTION
12/04/2003 PLUMBING - SEWER HCS CONNECT ROHAVER Approved IVRS - Inspection 0999*/ 1) MUST COMPLETE SEWER PIPING INSTALLATION, WATER TEST, RECALL FOR INSPECTION 2) NO RE-INSPECTION FEE ASSESSED AT THIS TIME
07/01/2004 ELECTRIC - SERVICE UPGRADE FGREER Approved IVRS - Inspection :*
07/01/2004 ELECTRIC - UFER FGREER Approved IVRS - Inspection :*
07/01/2004 MECHANICAL - INTERMEDIATE FGREER Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW