Inspection Status: Denied
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 02/26/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) FOOTING UNDER NORTH CARPORT WALL IS NOT PER 1/2 2) PROVIDE PROOF OF FOOTINGS FOR ENTIRE PROJECT 3) WEST 4 X 8 BEAM MUST BEAR ON AT LEAST 2/3 OF WIDTH 4) GROUND ALL METAL ELECTRIC BOXES ENTIRELY 5) PROVIDE PROOF OF POSTS AND FOOTING AT CARPORT SOUTH WALL 6) BLOCK CARPORT WALL CELLS ARE DIRTY. REMOVE ALL MORTAR AND DEBRIS 7) NO GAS PRESSURE TEST 8) PROVIDE PROOF OF UNDERGROUND PLUMBING INSPECTION OR EXPOSE 9) ELECTRIC JUNCTION BOXES CANNOT TO BE CONSEALED IN CEILING 10) NAIL PROTECT ALL PLUMBING/ELECTRIC WITHIN 1 1/4" OF STUD SURFACE 11) BOND GAS LINE 12) DUCTWORK NOT COMPLETE 13) REVISE PLAN FOR PEX PLUMBING 14) 1/4 AND 2/4 NOT COMPLIED WITH 15) PROVIDE MECHANICAL PLAN |