Permit: T02CM03689
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
4355 S SANTA RITA AV
Address NEW:
4355 S SANTA RITA AV
Apply Date:
08/06/2002
Applicant:
SONORAN EXPEDITING
Description:
TI:MANUFACTURING BUILDING
Contractors:
- HAZEN LTD , STEVE
Permit Reviews
Permit Number - T02CM03689
Permit Status: C of o
Permit Description: TI:MANUFACTURING BUILDING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/28/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 05/02/2003 | COMPLETED |
| 08/06/2002 | 3RD PARTY COMMERCIAL TI | 08/19/2002 | COMPLETED |
| 09/24/2002 | REVISION | 09/26/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM03689
Permit Status: C of o
Permit Description: TI:MANUFACTURING BUILDING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/06/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM03689
Permit Description: TI:MANUFACTURING BUILDING
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/29/2002 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | IVRS - Inspection 0000*OK TO COVER 2-4" PVC'S TEP TRANSFORMER. TO CT CAN CONCRETE ENCLOSE LAST 4-5' INTO TRANSFORMER. |
| 09/26/2002 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 09/30/2002 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) CONTRACTOR IS REQUESTING TEMP C OF O. 2.) TENANT HAS AMPLE EXISTING FACILITIES TO ACCOMODATE NECESSARY USAGE. THREE BATHROOMS. 3.) OK WITH PLUMBING INSPECTOR FOR TEMP C OF O. PENDING REVIEW BY S. LONG. |
| 09/30/2002 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | IVRS - Inspection 0000*FOR NEW EQUIP. BAYS ONLY. |
| 10/01/2002 | PERMIT FINALED | JYBARRA | Approved | |
| 10/01/2002 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
| 10/01/2002 | SIGN - FINAL | JYBARRA | Approved | NO SIGNS AT THIS TIME |
| 10/01/2002 | ENGINEERING - FINAL | JBRUCKME | Approved | |
| 10/01/2002 | FIRE - FINAL | LTHOMAS | Approved | OK FOR TEMP C OF O FOR TEMP POWER IN NEW PANELS |
| 10/01/2002 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 10/01/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 10/01/2002 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 10/01/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 10/01/2002 | ELECTRIC - TEMP POWER FOR TEST | JORTA | Approved | |
| 12/19/2002 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0999* 1.) APPEAR THAT INSTALLATION NO LONGER REFLECTS APPROVED PLAN PROVIDE ACCURATE AS BUILTS AS INSTALLED. 2.) 400A PNLS F & E NEED TO BE 22,000 RATED 3.) NEW LATHE'S & MILLS JAPAN ARE NOT LISTED 4.) PANEL SCHEDULES DO NOT REFLECT ACTUAL INSTALLATION AS BUILTS TO REFLECT CHANGES. LISTINGS REQUIRED PER NEC 110-3 PLEASE PROVIDE A LISTING FOR ALL UNLISTED EQUIPMENT AMERICAN OR FORIENG. |
| 12/19/2002 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 12/19/2002 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 12/19/2002 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 12/19/2002 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0999*1.) PROVIDE FINALS FROM OTHER TRADES. 2.) EGRESS ROUTES NEED TO COMPLY WITH ADA GUIDE LINES IE NO TWISTING OF KIND TO GET OUT. 3.) LOCK ON APA ROUTE MUST UNLOCK AUTOMATICALLY FROM EGRESS SIDE (ADA RESTROOM). 4.) ADA SIGNAGE TO BE 60" FROM FLOOR & MOUNTED ON WALL ON LATCH SIDE. ADA SIGNAGE SHOULD INCLUDE BRAILLE. |
| 12/19/2002 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 12/19/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000* 1.) CORRECTIONS MADE OK 2.) INSPECTOR SATISFIELD CONCERNING PREVIOUS INSPECTIONS. 3.) OK FOR C OF O PENDING ANY OTHER INSPECTION. |
| 12/20/2002 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000* |