Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02CM02009
Permit Details
Apply Date:
04/18/2002
Applicant:
THE IEF GROUP
Description:
TI:OFFICE
Architects:
- BRECKENRIDGE, KLINDT DUNCAN
Contractors:
- LEFCO INC ,
Permit Reviews
Permit Number - T02CM02009
Permit Status: C of o
Permit Description: TI:OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/16/2003 | RESUBMITTAL | 02/03/2003 | COMPLETED |
| 01/16/2003 | RESUBMITTAL - SITE | 02/03/2003 | COMPLETED |
| 02/19/2003 | RESUBMITTAL | 03/27/2003 | COMPLETED |
| 02/19/2003 | RESUBMITTAL - SITE | 03/27/2003 | COMPLETED |
| 04/14/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 04/21/2003 | COMPLETED |
| 04/18/2002 | COMMERCIAL TI | 07/22/2002 | COMPLETED |
| 07/30/2002 | RESUBMITTAL | 07/31/2002 | COMPLETED |
| 08/13/2002 | SITE | 09/13/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02009
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/18/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM02009
Permit Description: TI:OFFICE
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/24/2003 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*ABS DWV UNDERGROUND OK WATER TEST ONE RISER TO TEN FEET OK 2.) OK TO COVER. |
| 04/24/2003 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
| 05/12/2003 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) HAVE PLUMBER REVIEW SECTION 712.4.2 94 UPC TEST GUAGES 2.) MAY NOT CONNECT CONDENSATE WASTE TO A SINK TAILPIECE P-6 3.) ABS DWV THRU ROOF OK WATER TEST OK 4.) COPPER OK CONTRACTOR TO STRAP AND ISOLATE AS NEEDED. 5.) OK TO COVER WALLS SUBJECT TO ARCHECT RELOCATION OF CONDENSATE AT P-6. |
| 06/04/2003 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 06/04/2003 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 06/04/2003 | FRAMING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 06/13/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*/ 1) REVISED APPROVED PLAN ON SITE, OK TO COVER SINK FUNNEL DRAIN |
| 06/14/2003 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 08/20/2003 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
| 08/20/2003 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 08/20/2003 | ENGINEERING - FINAL | JSALINE | Approved | |
| 08/20/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000*/ 1) OK FOR C OF O |
| 08/20/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 08/20/2003 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
| 08/20/2003 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 08/20/2003 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 08/20/2003 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 08/20/2003 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 08/22/2003 | PERMIT FINALED | AQUIROZ | Approved | |
| 08/22/2003 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
| 08/22/2003 | PLUMBING - FINAL | RMYERS | Approved | 1) CORRECTIONS MADE OK 2) PLUMBING FINAL OK 3) OK FOR C OF O PENDING ANY OTHER INSPECTION 4) LAST INSPECTOR TO LEAVE GAS CARD |
| 08/22/2003 | ELECTRIC - FINAL | MCAPISTR | Approved | |
| 08/22/2003 | BUILDING - FINAL | AQUIROZ | Approved |