Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02CM01664
Permit Details
Apply Date:
04/01/2002
Applicant:
PEDERSEN, HAROLD SAMUEL
Description:
NEW:HOTEL
Architects:
- PEDERSEN, HAROLD SAMUEL
Contractors:
- P H I ,
Permit Reviews
Permit Number - T02CM01664
Permit Status: C of o
Permit Description: NEW:HOTEL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/15/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 01/15/2004 | COMPLETED |
02/13/2004 | RESUBMITTAL - SITE | 02/13/2004 | COMPLETED |
04/01/2002 | SITE | 07/10/2002 | COMPLETED |
04/01/2002 | 3RD PARTY REVIEW-COMMERCIAL | 07/10/2002 | COMPLETED |
10/06/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 10/06/2003 | COMPLETED |
10/23/2003 | 3RD PARTY REVIEW-COMMERCIAL | 11/21/2003 | COMPLETED |
12/09/2003 | SITE-REVISION | 01/08/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM01664
Permit Status: C of o
Permit Description: NEW:HOTEL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/01/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM01664
Permit Description: NEW:HOTEL
Total Completed Inspections - 43
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/21/2002 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000*3RD PHASE WRAP OK NEED REVISION ON FLOOR DRAINS & WATER SERVICE SIZE. |
10/21/2002 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
10/24/2002 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | IVRS - Inspection 0000* 80' 8RUNS 4" NORTH SIDE OF BLD OK TO COVER |
11/15/2002 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection 0000* |
11/15/2002 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* |
11/27/2002 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000*OFFICE LOCKED WILL NEED APPROVED PLAN & SPEC WILL NEED ARCH STAMP ON LETTER OF REVISION. SEE PLAN / FOR C O WILL NEED SPEC FOR WATER INSIDE. |
12/05/2002 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
12/19/2002 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
04/10/2003 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection 0000*TOWER OK. |
05/21/2003 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | 1ST FLOOR OVERHD PRESS. |
05/21/2003 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | Approval for 1st floor hydrostat test only. |
08/04/2003 | ELECTRIC - PROGRESS | MCAPISTR | Approved | |
10/01/2003 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000*/ 1) COMMON AREAS |
10/15/2003 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000*/ 1) PLEASE READ 103.5.1 94 UPC 2) PLEASE EXPOSE COMPLETLY ALL FITTINGS AND CONNECTIONS AT EACH END OF BLDG SEWER FOR INSPECTION. |
11/03/2003 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000*/ CONDENSATE DRAIN MAY NOT TERMINATE AT SINK TAILPIECE. SEE 807.2 94 UPC. |
11/05/2003 | MECHANICAL - ABOVE CEILING | IVR USER | Approved | IVRS - Ri canceled |
11/10/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000*/ CONDENSATE DRAIN, AIR HANDLER IN ATTIC OK. |
11/14/2003 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* ON FOOTING AT POOL |
11/24/2003 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000*/ 1) PRESSURE TEST OK. 2) GAS FLEXES UNDERSIZED TO WATER HTRS. |
11/25/2003 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
12/04/2003 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | IVRS - Inspection 0000* |
12/04/2003 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | IVRS - Inspection 0000*/ OK FOR TEMP POWER S.T.O.I. |
12/04/2003 | ELECTRIC - TEMP POWER FOR TEST | MCAPISTR | Approved | IVRS - Inspection 0000*/ PENDING POSTING OF BOND. CLEARANCE SUBJECT TO BOND AND ALL OTHER INSPECTORS SIGNING OFF. SENT TO TEP ON 12/5PM |
12/04/2003 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
12/04/2003 | BUILDING - TEMP POWER FOR TEST | AQUIROZ | Approved | IVRS - Inspection 0000* |
12/15/2003 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000*/ 2ND FLOOR UNITS AND HALLWAYS WITH STAIRWELLS. |
12/21/2003 | LANDSCAPE - FINAL | ACONNOR | Approved | LANDSCAPING IS REQUIRED TO BE INSTALLED PER APPROVED PLANS. (SEE PLANS DATED 12/09/04). PROVIDE APPROVED COPY OF PLANS W/ ORIGINAL STAMPS. PROVIDE BIKE PARKING AS SHOWN ON APPROVED PLANS. PROVIDE DUST CONTROL FOR DISTURBED AREA OUTSIDE OF THE PHASE 1 AREA (2" dg OR EQUAL) CANOPY TREES, NOT PALM TREES ARE REQUIRED ALONG WETMORE ROAD. FINISH ALL GROUNDCOVER WORK DECOMPOSED GRANETE etc. 1/21/04 FINISH STREET LANDSCAPE BORDER.1/21/04 |
12/24/2003 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*/ PROVIDE INSPECTION HISTORY WITH APPROVALS ON ALL REQUIRED INSPECTIONS - THEN YOU ARE READY FOR FINAL. DON'T FORGET LISTING, SHOWING APPROVAL OF CONCEALED "PRO PRESS" COPPER AND POOL AND POOL GAS APPROVAL. |
01/06/2004 | FIRE - ALARM FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
01/06/2004 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
01/07/2004 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000*/ 1) OK C OF O |
01/12/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
01/12/2004 | MECHANICAL - HOODS | CWILLIAM | Approved | |
01/16/2004 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
01/22/2004 | NPPO - FINAL | ACONNOR | Approved | |
01/22/2004 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
01/22/2004 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection 0000* |
01/22/2004 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection 0000* |
01/25/2004 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
02/05/2004 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | |
02/20/2004 | ENGINEERING - FINAL | JBRUCKME | Approved | |
02/20/2004 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
02/23/2004 | PERMIT FINALED | AQUIROZ | Approved |