Permit: T01EL02420
Permit Details
Apply Date:
09/27/2001
Applicant:
RIGGS, CHARLES R
Description:
UPGRADE:ELECTRIC
Contractors:
- SUN WESTERN CONTRACTORS
Permit Reviews
Permit Number - T01EL02420
Permit Status: Final
Permit Description: UPGRADE:ELECTRIC
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/22/2002 | ELECTRICAL | 08/26/2002 | COMPLETED |
10/17/2002 | ELECTRICAL | 10/17/2002 | COMPLETED |
11/15/2002 | ELECTRICAL | 11/15/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01EL02420
Permit Status: Final
Permit Description: UPGRADE:ELECTRIC
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/27/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T01EL02420
Permit Description: UPGRADE:ELECTRIC
Total Completed Inspections - 6
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/12/2002 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000*OK 2-1" PVC COATED RIDGID CONDUIT FROM PUMPS TO CANAPY COLUMN BUILDING #9. |
11/07/2002 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection 0000* |
11/07/2002 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000*NOT READ INSPECTION TO CONTINUE AMONG CORRECTION BELOW I WILL NEED TO CONTINUE A W/"BELOW SES IE. MCC-1 MCC 2,T-2, TRANSFER SWITCHES AND MORE. 1.) TORQUING LETTER RECEIVED OK 2.) NEED TO SEE SECONDARY TERMINATION ARRANGE W/T.E.P. AND CALL 791-5550 X 1136 FOR SCHEDULING. 3.) HEAD ROOM CLEARANCE IN FRONT OF SES IN VIOL. OF 110-26 4.) MIN GROUND SYSTEM RODS, STEEL, WITH WATER AND GAS BOND. 5.) SECODNARY CONDUCTOR CANNOTBE VERIFIED PANEL LB AND W WIRING NOT PER APPROVED PLAN 6.) MCC-2 NEED 1/0 GRND EACH. ALSO MCC-1. |
12/19/2002 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0000*1.) GROUND RODS 2-6' APART 4.) INSULATION ON SEC LL HAND SECTION. SES & CONDUCTORS OK MBJ OK. 1.) SINCE THIS SWITCH GEAR WAS ONLY REPLACED NOT INCREASED OK FOR EXISTING GAS LINE TO REMAIN. 2.) 2 GROUND RODS ARE REQUIRED TO COMPLETE GROUNDING SYSTEM. 3.) HAVE INSPECTED TIE IN ON GEAR FROM TEP AND VERIFIED TERMINATION, MAIN BONDING JUMPER, REQUESTED 2 EXISTING CONDUITS TO BE RETIED TO GROUND BAR FROM BUSHINGS 4.) APPLYING INSULATION ON BOTTOMM LEFT HAND CONDUCTORS TOO NEAR FRAME. 5.) VERIFIED CHANGE FROM 1/0 GROUNDS TO NEUTRAL FOR MCC-1 & 2 ALSO 350 MCM NEUTRALS TO GROUND NEUTRAL FOR MCC-1 & 2. CONTRACTOR HAD AN APPROVED CHANGE ON SITE. |
03/13/2003 | PERMIT FINALED | RMAJUTA | Approved | |
03/13/2003 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved |