| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/09/2003 | REVISION | 01/10/2003 | COMPLETED |
| 01/23/2003 | REVISION | 01/23/2003 | COMPLETED |
| 07/25/2001 | 3RD PARTY REVIEW-COMMERCIAL | 11/23/2001 | COMPLETED |
| 07/25/2001 | SITE | 10/22/2001 | COMPLETED |
| 09/04/2002 | REVISION | 11/14/2002 | COMPLETED |
| 10/22/2001 | SITE | 10/31/2001 | COMPLETED |
| 11/01/2001 | RESUBMITTAL | 03/06/2002 | COMPLETED |
| 11/14/2002 | REVISION | 11/18/2002 | COMPLETED |
| 11/23/2001 | RESUBMITTAL | 03/06/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM03651
Permit Status: C of o
Permit Description: NEW:RETAIL
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/25/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM03651
Permit Description: NEW:RETAIL
Total Completed Inspections - 31
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/28/2002 | PLUMBING - ROUGH, SOIL | FMCCLURE | Approved | IVRS - Inspection 0000*UNDERGROUND WASTE ONLY IN BUILDING OK TO COVER. |
| 08/29/2002 | EXCAVATION/LAYOUT REBAR & ZON | RSUBA | Approved | IVRS - Inspection 0000*OK BUILDING EXCAVATION LAYOUT REBAR. |
| 09/03/2002 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000*FOOTING POURED. THIS INSPECTOR DID NOT INSPECT THE WIRE TO REBAR CONNECTION. OTHER STEEL ITEMS ABOVE SLAB WILL BE INSPECTED WHEN INSTALLED PER GROUNDING. DIAGRAM ON PLAN SHEET E-2. |
| 09/03/2002 | BUILDING PRE-SLAB | RSUBA | Approved | IVRS - Inspection 0000*WRAP ALL PLUMBING ABS PIPING THROUGH SLAB. PRIOR TO POUR. |
| 10/25/2002 | BUILDING ABOVE CEILING | RSUBA | Approved | IVRS - Inspection 0000* |
| 10/25/2002 | EXT METAL CLIPS/EXT SHEATHING | RSUBA | Approved | IVRS - Inspection 0000* |
| 10/30/2002 | FRAMING | RSUBA | Approved | IVRS - Inspection 0000* |
| 11/15/2002 | U VALUE FOR WINDOW | RSUBA | Approved | IVRS - Inspection 0000* |
| 11/19/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*OK TO SHEET ROCK REST ROOMS. |
| 11/20/2002 | PLUMBING - INTERMEDIATE | FMCCLURE | Approved | IVRS - Inspection 0000* |
| 11/22/2002 | SHEET ROCK NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
| 11/25/2002 | PLUMBING - SEWER HCS CONNECT | FMCCLURE | Approved | IVRS - Inspection 0000* |
| 11/26/2002 | PLUMBING - YARD WTR LINE/TEST | FMCCLURE | Approved | |
| 12/17/2002 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 12/17/2002 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 01/14/2003 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 01/14/2003 | ELECTRIC - ABOVE CEILING | JORTA | Approved | IVRS - Inspection 0000*RODS APPROVED M.C. CABLE APPROVED. |
| 01/23/2003 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | IVRS - Inspection 0000* |
| 01/23/2003 | PLUMBING - TEMP POWER FOR TEST | TRINIVJR | Approved | IVRS - Inspection 0000*OK FOR TEMP POWER. |
| 01/23/2003 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | IVRS - Inspection 0000* |
| 01/24/2003 | ELECTRIC - TEMP POWER FOR TEST | RMAJUTA | Approved | IVRS - Inspection 0000*SENT TO TEP ON 1/27/03 AT 9:15AM OK TO CLEAR TEMP POWER ALL OTHER INSPECTORS SIGNED OFF. 1.) MAIN 200A DISCONNECT OUTSIDE THE LOAD BASE TO BE RELOCATED TO J-FUSE SLOT SO J-SURE WILL BE CLAMPED BY 2 SECTIONS OF BASE. 2.) USE ONLY POWER RECEPTACLES AND LIGHTING AC NOT IN ROOF COOLERS NOT CHECKED. 3.) REPLACE 60AMP SYLVANIA BKR WITH TYPE. |
| 01/31/2003 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O |
| 01/31/2003 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 01/31/2003 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
| 02/04/2003 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
| 02/11/2003 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000* |
| 02/12/2003 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
| 02/18/2003 | LANDSCAPE - FINAL | PGILBERT | Approved | |
| 02/27/2003 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 03/10/2003 | PERMIT FINALED | JEGAN | Approved | |
| 03/10/2003 | FIRE - FINAL | JEGAN | Approved |