Permit: T01CM01497
Permit Details
Apply Date:
03/28/2001
Applicant:
N/A
Description:
TI:OFFICE
Architects:
- ACORN, KIM BRIAN
Contractors:
- DIVISION II CONSTRUCTION COMPANY
- FLUORESCO LIGHTING MAINTENANCE C
Permit Reviews
Permit Number - T01CM01497
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/15/2002 | REVISION | 05/09/2002 | COMPLETED |
03/28/2001 | 3RD PARTY COMMERCIAL TI | 07/03/2001 | COMPLETED |
03/28/2001 | SITE | 05/07/2001 | COMPLETED |
05/09/2002 | REVISION | 05/09/2002 | COMPLETED |
05/14/2001 | SITE | 06/13/2001 | COMPLETED |
06/04/2002 | REVISION | 06/21/2002 | COMPLETED |
06/20/2001 | RESUBMITTAL | 07/06/2001 | COMPLETED |
07/02/2001 | SITE | 07/10/2001 | COMPLETED |
07/06/2001 | RESUBMITTAL | 07/10/2001 | COMPLETED |
09/17/2002 | REVISION | 10/02/2002 | COMPLETED |
10/04/2001 | REVISION | 10/04/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM01497
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
03/28/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM01497
Permit Description: TI:OFFICE
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/20/2001 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
07/26/2001 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000* |
08/05/2001 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*1.) ABS DWV UNDERGROUND OK WATER TEST OK 2.) OK TO BACKFILL. |
08/10/2001 | ELECTRIC - CABLE DROP | JORTA | Approved | IVRS - Inspection 0000* |
08/19/2001 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) 60# AIR TEST OK 2.) REMOVE WATER FROM TRENCH, AND BED GAS PIPE WITH APPROVED CLEAN FILL.3.) DONT FORGET, PRESSURE REGULATORS NEED TO BE TAGGED, AND REGULATOR VENT OPENING NEEDS TO BE PROTECTED AGAINST WATER AND OTHER CONTAMINANTS 4.) OK TO BACKFILL TRENCH. |
08/28/2001 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
09/18/2001 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
10/05/2001 | PLUMBING - INTERMEDIATE | FMCCLURE | Approved | IVRS - Inspection 0000* |
10/09/2001 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
11/08/2001 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000*1.) PLUMBING ABOVE CEILING OK CONTRACTOR TO INSURE ABS SUPPORTED EVERY 4' MAX 2.) GAS FOR PAINT BOOTHS OK MECHANICAL INSPECTOR APPROVED BOOTHS. 3.) UCC LEFT AT METER GAS RELEASED BEFORE PLUMBING FINAL BECAUSE OF SCHEDULING DIFFERENCES. OK FOR GAS. |
11/14/2001 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | OK TO SET CEIL. TILES. |
11/14/2001 | BUILDING ABOVE CEILING | DWITT | Approved | |
12/04/2001 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
12/05/2001 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
12/14/2001 | FIRE SPKLR - OH PIPING & HYDRO | FIRE | Approved | |
12/14/2001 | FIRE SPKLR - UG PIPING FLUSH | FIRE | Approved | |
12/14/2001 | FIRE SPKLR - UG, PIPING, HYDRO | FIRE | Approved | |
12/19/2001 | NPPO - FINAL | PGILBERT | Approved | OK FOR TEMP C OF O. |
12/19/2001 | LANDSCAPE - FINAL | PGILBERT | Approved | OK FOR TEMP C OF O. |
12/19/2001 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0999*1.) THERE ARE TWO OUTSTANDING ISSUES ON THIS JOBSITE THAT NEED TO BE RESOLVED C.D. ON SINKS & CLEARANCES ON WATER CLOSETS THESE NEED TO GO THRU ARCHETECT, IN THE MEANTIME, THERE IS NO REASON A TEMP C OF O. CANNOT BE ISSUED. 2.) OK FOR TEMP C OF O. PENDING ANY OTHER INSPECTIONS. |
12/19/2001 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000*PARTIAL OFFICE AREA COMPLETE 1.) OK FOR TEMP C OF O. FOR OFFICE & BATHROOMS 2.) I STILL NEED PLUMBING & LANDSCAPE FINAL. |
12/21/2001 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
12/28/2001 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | 1.) THE AIR LINE BELOW THE DISCONNECTS FOR THE COMPRESSOR IS IN THE WORKING SPACE AS PER CODE 110-26. |
11/18/2002 | ELECTRIC - UNDERGROUND | JORTA | Approved | |
11/22/2002 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | |
11/26/2002 | PERMIT FINALED | LHANLY | Approved |