Permit: T00CM06226
Permit Details
Apply Date:
12/29/2000
Applicant:
N/A
Description:
TOWNHOME & PORCH
Contractors:
- OLLANIK CONSTRUCTION
Permit Reviews
Permit Number - T00CM06226
Permit Status: C of o
Permit Description: TOWNHOME & PORCH
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/08/2001 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 02/15/2001 | COMPLETED |
| 02/15/2001 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 05/15/2001 | COMPLETED |
| 05/15/2001 | REVISION | 05/25/2001 | COMPLETED |
| 06/22/2001 | REVISION | 07/03/2001 | COMPLETED |
| 11/27/2001 | REVISION | 11/27/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T00CM06226
Permit Description: TOWNHOME & PORCH
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/28/2001 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection 0000*OK UPPER |
| 06/28/2001 | STEM WALL/RETAINING WALL | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 06/28/2001 | EXCAVATION/LAYOUT REBAR & ZON | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 07/17/2001 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000*ROUGH SOIL & COPPER UNDER SLAD OK IN CASITA. |
| 07/17/2001 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000*BUILDING OK STILL NEED TO SEE CASITA. |
| 07/27/2001 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | IVRS - Inspection 0000*TEST ON 1 1/4" 1," 3/4 SITE WATER TO ABOVE UNITS OK. |
| 11/05/2001 | REINFORCED MASONRY PRE-GROUT | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 11/14/2001 | ROOF NAILING | EMONAHAN | Approved | |
| 11/14/2001 | EXT METAL CLIPS/EXT SHEATHING | EMONAHAN | Approved | |
| 12/28/2001 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 12/28/2001 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000*NEED APPROVED PLAN. |
| 12/30/2001 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0999*1.) BOX FILL FOR DONDUCTORS IN FAN PAN OVER FILLED 370 2.) PROTECT CONDUCTORS AT BEAM AND STUDS 300-4. 3.) PLEASE PROVIDE GROUND FOR SWITCHES. 4.) GROUND ALL METAL BOXES. 5.) NEED TO HAVE WIRE CONNECTORS AT EXHAUST FANS 373-5 PANEL & METAL BOXES. 6.) FILL UNUSED OPENING IN BOXES. 7.)PANEL TO BE MADE UP AS PER MANUFACTURES SPECS. 8.) PLEASE PROVIDE FLEX FOR A/C & WATER HEATER STUBS. 9.) STRAP NM CABLE WITH IN 12" OF BOXES. |
| 01/03/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 01/03/2002 | FRAMING | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 01/16/2002 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
| 01/28/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 02/05/2002 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 02/07/2002 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 05/23/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
| 05/24/2002 | PERMIT FINALED | AMATHIES | Approved | |
| 05/24/2002 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/24/2002 | U VALUE FOR WINDOW | AMATHIES | Approved | |
| 05/29/2002 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 05/29/2002 | PLUMBING - SEWER HCS CONNECT | JSTANLEY | Approved | |
| 05/30/2002 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000*OK FINAL. |
| 05/30/2002 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 10/22/2013 | FIRE - FINAL | LHANLY | Approved | this area was approved by fire 10 years ago |