Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/30/2002 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*OK FINAL. |
| 05/29/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0935*1.) AN EXTENDER RING IS NEEDED WHERE DEVICE IS PAST 1/8" OF BOX. 2.) SEALTITE FITTING LOOSE AT A/C ON CASITA 3.) CAN NOT ACCESS CASITA FOR INSPECTION. A REFEE HAS BEEN ASSESSED. |
| 05/24/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*FLOORING CONTRACTOR DIDNT WANT ANYBODY TO WALK ON STAIRS WHILE FINISHING. |
| 05/23/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*AC UNIT NEED 36" CLEAR FROM UNIT. |
| 05/22/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*1.) INSTALL THERMOSTAT 2.) OUTSIDE FIXTURES MISSING 3.) OUTSIDE UNIT MISSING FOR AC HAVE ALL ITEMS ELECTRICALLY WORKING SO UNIT CAN BE TESTED. |
| 05/21/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) USE AN APPROVED CONNECTOR AT BATHBARS. 2.) PROVIDE EXTENDER RUGS WHERE DEVICES ARE LESS THAN 1/8" INTO COMBUSTABLES. NO WORK PROGRESS SINCE 5-20-02 INSPECTION A REFEE MAYBE ASSESSED IF WORK PROGRESS IS NOT COMPLETED BE FOR NEXT INSPECTION. |
| 05/20/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) FILL UNUSED OPENING IN FIRE ALARM BELL BOX 2.) PLEASE THIGHTEN SEAL TITE FITTING FOR FLOW SWITCH. 3.) A CONNECTOR IS NEEDED AT BATH BARS 373-5. 4.) EXTENDER RUGS ARE NEEDED FOR DEVICES INTO COMBUSTABLES. 5.) TIGHTEN FITTINGS AT WATER HEATER. 6.) PLEASE MAINTANCE CLEARENCE FOR LIGHT FIXTURES AND SHELVES 410- 7.) PANEL BUSS NEED TO BE CLEANED OF FORIGEN MATERIAL 110-12. 8.) INSTALL ALL STRANDS OF CONDUCTORS UNDER LUGS. |
| 05/19/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |