Permit: T00CM06226


Addresses:

3009 N GAIA PL

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/30/2002 ELECTRIC - FINAL Approved IVRS - Inspection 0000*OK FINAL.
05/29/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0935*1.) AN EXTENDER RING IS NEEDED WHERE DEVICE IS PAST 1/8" OF BOX. 2.) SEALTITE FITTING LOOSE AT A/C ON CASITA 3.) CAN NOT ACCESS CASITA FOR INSPECTION. A REFEE HAS BEEN ASSESSED.
05/24/2002 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*FLOORING CONTRACTOR DIDNT WANT ANYBODY TO WALK ON STAIRS WHILE FINISHING.
05/23/2002 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*AC UNIT NEED 36" CLEAR FROM UNIT.
05/22/2002 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) INSTALL THERMOSTAT 2.) OUTSIDE FIXTURES MISSING 3.) OUTSIDE UNIT MISSING FOR AC HAVE ALL ITEMS ELECTRICALLY WORKING SO UNIT CAN BE TESTED.
05/21/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0999*1.) USE AN APPROVED CONNECTOR AT BATHBARS. 2.) PROVIDE EXTENDER RUGS WHERE DEVICES ARE LESS THAN 1/8" INTO COMBUSTABLES. NO WORK PROGRESS SINCE 5-20-02 INSPECTION A REFEE MAYBE ASSESSED IF WORK PROGRESS IS NOT COMPLETED BE FOR NEXT INSPECTION.
05/20/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0999*1.) FILL UNUSED OPENING IN FIRE ALARM BELL BOX 2.) PLEASE THIGHTEN SEAL TITE FITTING FOR FLOW SWITCH. 3.) A CONNECTOR IS NEEDED AT BATH BARS 373-5. 4.) EXTENDER RUGS ARE NEEDED FOR DEVICES INTO COMBUSTABLES. 5.) TIGHTEN FITTINGS AT WATER HEATER. 6.) PLEASE MAINTANCE CLEARENCE FOR LIGHT FIXTURES AND SHELVES 410- 7.) PANEL BUSS NEED TO BE CLEANED OF FORIGEN MATERIAL 110-12. 8.) INSTALL ALL STRANDS OF CONDUCTORS UNDER LUGS.
05/19/2002 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection 0000*