Permit: T00CM05456
Permit Details
Apply Date:
11/07/2000
Applicant:
WARREN MICHAELS
Description:
SFR:TD#14-81-63
Architects:
- LANNING, ROBERT SCOTT
Permit Reviews
Permit Number - T00CM05456
Permit Status: C of o
Permit Description: SFR:TD#14-81-63
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
11/07/2000 | RESIDENTIAL BLDG/ZONING/FLOOD | 11/27/2000 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T00CM05456
Permit Description: SFR:TD#14-81-63
Total Completed Inspections - 18
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/28/2001 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000* OK TO COVER |
04/16/2001 | REINFORCED MASONRY PRE-GROUT | DWITT | Approved | IVRS - Inspection 0000* |
05/08/2001 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | |
06/22/2001 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000* |
06/22/2001 | U VALUE FOR WINDOW | DWITT | Approved | IVRS - Inspection 0000* |
06/25/2001 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
06/28/2001 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) OK FOR DRYWALL. |
06/28/2001 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection 0000*MUST INSTALL BOND JUMPER FOR ALL SWITCHES |
07/06/2001 | SHEET ROCK NAILING | DWITT | Approved | IVRS - Inspection 0000* |
08/27/2001 | ELECTRIC - CABLE DROP | JORTA | Approved | IVRS - Inspection 0000* |
11/07/2001 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
11/08/2001 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
11/28/2001 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0000* |
11/29/2001 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0999*1.) PLEASE READ NOTE #2 ON 11/07/01. EXPOSE ALL PIPING AND FITTINGS AND CALL FOR INSPECTION. |
11/29/2001 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000* |
11/29/2001 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
12/05/2001 | PLUMBING - YARD WTR LINE/TEST | SLONG | Approved | 1.) YARD WATER COVERED BEFORE INSPECTION 2.) INSPECTIONS MANAGER APPROVED PATHOLING OF WATER LINE METHOD OF POTHOLLING. EXPOSE FITTINGS AT METER EXPOSE ALL COUPLINGS AND FITTING AT LEAST EVERY 20 FEET EXPOSE COPPER AT SERVICE AND TRANSITION FITTING. 609.1 ALL WATER SERVICE YARD PIPING SHALL HAVE A MINIMUM OF 12" OF COVER. IS 7 301.1.3 IDENTIFYING MARKINGS ON PIPE AND FITTINGS SHALL BE VISIBLE WITHOUT MATERIALS WHEN READY FOR INSPECTION CALL STEVE LONG. |
02/07/2005 | PERMIT FINALED | RMAJUTA | Approved |