Permit: T00CM05456

Parcel: 117142770


Addresses:

630 S RUBIO AV


Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Permit Number - T00CM05456

Inspection Description - PLUMBING - YARD WTR LINE/TEST

Inspection Status - Approved

Date Description Inspector Results Comments
12/05/2001 PLUMBING - YARD WTR LINE/TEST Approved 1.) YARD WATER COVERED BEFORE INSPECTION 2.) INSPECTIONS MANAGER APPROVED PATHOLING OF WATER LINE METHOD OF POTHOLLING. EXPOSE FITTINGS AT METER EXPOSE ALL COUPLINGS AND FITTING AT LEAST EVERY 20 FEET EXPOSE COPPER AT SERVICE AND TRANSITION FITTING. 609.1 ALL WATER SERVICE YARD PIPING SHALL HAVE A MINIMUM OF 12" OF COVER. IS 7 301.1.3 IDENTIFYING MARKINGS ON PIPE AND FITTINGS SHALL BE VISIBLE WITHOUT MATERIALS WHEN READY FOR INSPECTION CALL STEVE LONG.