Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T00CM05456
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/23/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) PLUMBING FINAL OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS 4.) UCC LEFT AT METER. | |
01/21/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) FINISH CAULKING FIXTURES 2.) A WOOD SCREW, OR LAG BOLT INTO AN ABS C O. PLUG. IS NOT APPROVED. USE AN APPROVED TAPPED CO PLUG AND APPROVED SCREW. 3.) A CONDENSATE DRAIN MAY NOT TAP INTO A TRAP ARM. REMOVE CONDENSATE DRAIN, REPAIR TRAP ARM AND CALL FOR INSPECTION BEFORE COVERING. | |
11/29/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) PLEASE READ NOTE #2 ON 11/07/01. EXPOSE ALL PIPING AND FITTINGS AND CALL FOR INSPECTION. | |
11/28/2001 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*1.)NOT READY FOR INSPECTION. | |
11/07/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*POST YOUR ADDRESS 2.) PLEASE PROVIDE COMPLETE INSPECTION HISTORY REQ'D 03040 PLUMBING YARDWATER. 3.) NO PLAN ON SITE 4.) TRAP ARMS MAY ONLY CHANGE DIRECTION 90 WITHOUT CLEAN OUT. 5.) WATER CLOSETS REQUIRE 15" FROM SIDEWALL TO CENTER 6.) THIS IS NOT A PUNCH LIST AND MAY NOT INCLUDE ALL CODE INFRACTIONS YOUR PLUMBER NEEDS TO WALK THRU THIS JOB TO INSURE ITS COMPLETENESS. |