Permit: T00CM01578
Permit Details
Apply Date:
03/28/2000
Applicant:
GUTIERREZ LUIS G
Description:
SPA:ABOVE GROUND
Outstanding Inspections
Permit Status: Expired
Permit Number: T00CM01578
Permite Description: SPA:ABOVE GROUND
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2000 | BUILDING - FINAL | N/A | Partial Approval | PARTIAL APPROVAL |
| 04/07/2000 | ELECTRIC - FINAL | N/A | Correction Required | ADDTL COMMS - 1. ELECTRICIAN VERIFY THAT THE NEUTRAL BUSS AT THE SUB-PANEL IS INSULATED FROM THE CAN. 2. ID THE SPA BREAKERS OK 3. REGARDING THE 12 GA CONDUCTORS FROM THE SUB-PANEL TO THE PATIO AREA NOT YET CONNECTED. IT APPEARS THAT YOU WILL BE SHORT ON BREAKER SPACE FOR THESE CONDUCTORS. NO DOUBLE LUGGING AND BE SURE TO USE BREAKERS WHICH ARE APPROVED FOR THE SUB. PANEL. ID ALL BREAKERS. SUGGESTIONS: RUN GAS LINE ABOVE GRADE IN CARPORT 2. PROVIDE SHEET METAL FLASHING TO PROTECT WATER LINE WHERE IT PASSES OVER STEP TO FURNACE. 3. PROVIDE A LISTED VENT CAP ON THE WATER HEATER VENT. WE NOW REQUIRE 2 DRIVEN GROUNDS (6 APART) AT THE ELECTRICAL SERVICE. I RECOMMEND ADDING ANOTHER GROUND ROD. |
| 05/17/2000 | ELECTRIC - INTERMEDIATE | N/A | Correction Required | ADDTL COMMS - CORRECTION NOTICE OF 4/5/00, ITEM 8 REQD THE BONDING OF ANY METAL W/IN 5 OF THE INSIDE WALL OF THE SPA. THE NEW FENCING IS APPROX. 46 FROM THE INSIDE WALL. THE SPA MUST BE MOVED TO PROVIDE THE 5 DISTANCE OR BOND THE FENCE. SECTION680-41 (D)(4). REGARDING THECONDUCTORS RUNNING TO THE PATIO AREA... DO YOU WANT TO RUN THOSE ON A SEPARATE PERMIT SO THE SPA CAN BE FINALLED AFTER THE ABOVE CORRECTION IS COMPLETED. |