Permit: T00CM01578

Parcel: 12412197D


Addresses:

1421 E 13TH ST

Inspection Status: Correction Required

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
05/17/2000 ELECTRIC - INTERMEDIATE Correction Required ADDTL COMMS - CORRECTION NOTICE OF 4/5/00, ITEM 8 REQD THE BONDING OF ANY METAL W/IN 5 OF THE INSIDE WALL OF THE SPA. THE NEW FENCING IS APPROX. 46 FROM THE INSIDE WALL. THE SPA MUST BE MOVED TO PROVIDE THE 5 DISTANCE OR BOND THE FENCE. SECTION680-41 (D)(4). REGARDING THECONDUCTORS RUNNING TO THE PATIO AREA... DO YOU WANT TO RUN THOSE ON A SEPARATE PERMIT SO THE SPA CAN BE FINALLED AFTER THE ABOVE CORRECTION IS COMPLETED.
05/17/2000 ELECTRIC - INTERMEDIATE Partial Approval METAL FENCE NOT BONDED
04/07/2000 ELECTRIC - INTERMEDIATE Correction Required ADDTL COMMS - ELECTRICIAN VERIFY THAT THE NEUTRAL BUSS AT THE SUB-PANEL IS INSULATED FROM THE PANEL. 2.ID THE SPA BREAKER. 3.REGARDING THE 12 GAUGE CONDUCTORS FROM THE SUB-PANEL TO THE PATIO AREA (NOT YET CONNECTED). IT APPEARS THAT YOU WILL BE SHORT ON BREAKER SPACE FOR THESE CONDUCTORS. nO DOUBLE LUGGING AND BE SURE TO USE BREAKERS THAT ARE APPROVED FOR USE WITH THE SUB-PANEL. ID ALL BREAKERS. I RECOMMEND THAT YOU RUN THE GAS LINE ABOVE GRADE IN THE CARPORT AREA; PROVIDE SHEET METAL FLASHING TO PROTECT WATER PIPING WHERE IT PASSES OVER STEP TO FURNACE ROOM; PROVIDE A LISTED VENT CAP ON THE WATER HEATER VENT;ADD A SECOND GROUND ROD 6 FROM THE ORIGINAL ROD.
04/07/2000 ELECTRIC - INTERMEDIATE Partial Approval PARTIAL APPROVAL
04/05/2000 ELECTRIC - INTERMEDIATE Correction Required ADDTL COMMS - 1.NEED PERMIT FOR GAS LINE. 2. NEED LETTER FROM HOMEOWNER STATING THAT THE GAS LINE TRENCH IS 18 DEEP WITH A CONTINUOUS TRACER WIRE. INDICATE THE TYPE OF MATERIAL USED, THE PSI OF THE PRESSURE TEST AND THAT AN APPROVED TRANSITION FITTING WAS USED(GAS LINE COVERED W/O INSPECTION). 3. ID SPA BREAKER (SPA NOT ON SITE FOR THIS INSPECTION, REQD BREAKER SIZE UNKNOWN AT THIS TIME). 4. PROVIDE A HOSE BIBB BACKFLOW DEVICE ON NEW HOSE BIBB. 5. WITH ITEM #2 INCLUDE WATER LINE BURIAL DEPTH AND TYPE OF MATERIAL. 6. AT SUB-PANEL SEPARATE NEUTRALS AND GROUNDS. ONE CONDUCTOR PER LUG. 7. ONE GFI PROTECTED OUTLET REQD 10-20 FROM SPA. 8. BOND ANY METAL WITHIN 5 OF SPA.
04/05/2000 ELECTRIC - INTERMEDIATE Denied MULT. CORRECTIONS SEE F6