Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address NEW:
1225 W IRVINGTON RD
Apply Date:
03/17/2000
Applicant:
WOBKEN, TERRY GEORGE
Description:
NEW:RETAIL
Architects:
  • WOBKEN, TERRY GEORGE
Contractors:
  • WOODS INC , JOE E

Permit Reviews

Permit Number - T00CM01377
Permit Status: C of o
Permit Description: NEW:RETAIL
Start Date Submittal Complete Date Status  
01/02/2001 REVISION 01/02/2001 COMPLETED Review Details
01/16/2001 REVISION 02/05/2001 COMPLETED Review Details
01/17/2001 REVISION 01/26/2001 COMPLETED Review Details
02/05/2001 REVISION 02/05/2001 COMPLETED Review Details
02/05/2001 REVISION 02/12/2001 COMPLETED Review Details
02/23/2001 REVISION 03/06/2001 COMPLETED Review Details
03/06/2001 RESUBMITTAL 03/08/2001 COMPLETED Review Details
03/08/2001 REVISION 04/16/2001 COMPLETED Review Details
04/16/2001 RESUBMITTAL 04/30/2001 COMPLETED Review Details
04/18/2001 REVISION 04/30/2001 COMPLETED Review Details
07/18/2000 COMMERCIAL NEW 08/28/2000 COMPLETED Review Details
08/28/2000 COMMERCIAL NEW 10/04/2000 COMPLETED Review Details
08/28/2000 SITE 09/19/2000 COMPLETED Review Details
09/19/2000 SITE 10/09/2000 COMPLETED Review Details
10/04/2000 RESUBMITTAL 10/05/2000 COMPLETED Review Details
12/11/2000 REVISION 12/18/2000 COMPLETED Review Details
12/18/2000 REVISION 01/26/2001 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T00CM01377
Permit Description: NEW:RETAIL
Total Completed Inspections - 32
Date Description Inspector Results Comments
11/28/2000 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection 0000*
OK UNDERGROUND 4" (4) FEEDERS STUB OUT OF ELECTRIC FRROM TO OUTSIDE OF BLDG
12/04/2000 EXCAVATION/LAYOUT REBAR & ZON DWITT Approved IVRS - Inspection 0000*
ONE F5.5 AT J, 3
12/05/2000 BUILDING PRE-SLAB DWITT Approved IVRS - Inspection 0000*
PARTIAL ALL EXCEPT CLOSURE STRIP
12/06/2000 PLUMBING - ROUGH, SOIL RMYERS Approved NEED TO SEE REVISED APPROVED PLAN BEFORE INSPECTION
12/21/2000 STEM WALL/RETAINING WALL DWITT Approved RE BAR TILT PANEL
12/27/2000 ELECTRIC - TEMPORARY POLE JORTA Approved IVRS - Inspection 0000*
12/27/2000 ELECTRIC - INTERMEDIATE JORTA Approved IVRS - Inspection 0000*
12/27/2000 FRAMING DWITT Approved IVRS - Inspection 0000*
PROVIDE 50% TIES
COMPLETE STEEL
CONFIRM TAILS OF BENT BARS ARE PROPERLY POSTIONED
01/05/2001 ELECTRIC - UFER JORTA Approved IVRS - Inspection 0000*
UFER 20 FT MIN AND ON 30' MIN REBAR X-OTHER WISE WELD AND MECHANICALLY CONNECTED
02/09/2001 ROOF NAILING DWITT Approved IVRS - Inspection 0000*
03/22/2001 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0000* INSTALL REGULATORS AND WARNINGS, I WILL CHECK THEM ON FINAL
04/05/2001 BUILDING ABOVE CEILING DWITT Approved IVRS - Inspection 0000*
04/19/2001 STUCCO MESH AMATHIES Approved IVRS - Inspection 0000*
05/09/2001 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000* 1) YARD WATER LINE FROM METER THRU RPBP TO BLDG OK PRESSURE TEST OK
2) SUPPLY CERTIFICATION OF RPBP BY FINAL INSP.
3) OK TO BACKFILL
05/24/2001 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection 0000*
05/24/2001 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection 0000*
05/24/2001 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection 0000*
05/24/2001 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*1)ROOF DRAIN S IN FRONT OF BUILDING (2) OK WATER TEST OK.OK TO DRAIN AND 2 HANGERS ON HORIZONTIAL PIPE.2)90 DEGREE TURN DOWN W/SCREEN OK ON GAS REGULATOR.3)VENT ON INTERIOR GAS REGULATOR OK.
06/12/2001 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
06/19/2001 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*1)ALL CORRECTIONS MADE OK.
MED. PRESS GAS REQULATORS (3) ORDERED TO BE INSTALLED BY PLUMBING CONTRACTOR NO LATER THAN 062101.2)OK FOR C OF O PENDING ANY OTHER INSPECTIONS.3)UCC LEFT AT METER.
07/18/2001 OUTDOOR LIGHTING FINAL JORTA Approved IVRS - Inspection 0000*READY FOR FINAL WILL HAVE SHIELDS FOR LITE
07/18/2001 ELECTRIC - FINAL JORTA Approved
07/19/2001 BUILDING - FINAL DWITT Approved IVRS - Inspection 0000*
07/23/2001 FIRE - LANE SIGNS FIRE Approved
07/23/2001 FIRE - HYDRANTS FIRE Approved
07/23/2001 FIRE SPKLR - FINAL FIRE Approved
07/23/2001 FIRE SPKLR - OH PIPING & HYDRO FIRE Approved
07/23/2001 FIRE SPKLR - UG PIPING FLUSH FIRE Approved
07/23/2001 FIRE SPKLR - UG, PIPING, HYDRO FIRE Approved
07/23/2001 SHEET ROCK NAILING DWITT Approved
07/23/2001 EXT METAL CLIPS/EXT SHEATHING DWITT Approved
12/19/2001 ENGINEERING - FINAL DROBERTS Approved