Permit: T00CM01377

Parcel: 13705505D


Addresses:

1225 W IRVINGTON RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T00CM01377

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/24/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*1)ROOF DRAIN S IN FRONT OF BUILDING (2) OK WATER TEST OK.OK TO DRAIN AND 2 HANGERS ON HORIZONTIAL PIPE.2)90 DEGREE TURN DOWN W/SCREEN OK ON GAS REGULATOR.3)VENT ON INTERIOR GAS REGULATOR OK.
05/02/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) RAIN LEADERS IN GARDEN CENTER CLOUMNS OK WATER TEST OK SUPPORTS AND FITTINGS IN COLUMN VERIFIED BY HANDICAM
2) RED LINE GAS ROUTING ON AS BUILTS RE PRESSURE TEST SYSTEM 60# OK 3) CONDENSATE TRAP APPROVAL DEPENDANT ON ACCEPTANCE BY G.C. AND TARGET
04/20/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* NOT READY
04/19/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) HOSE BIBBS IN GARDEN CENTER OK, PRESSURE TEST OK 2) DRINKING FOUNTAIN IN GARDEN CENTER OK, OK TO COVER
3) CONDENSATE TRAPS ON ROOF FOR UNITS (ABS) APPROVED BY MANUFACTURER AND TARGET, WASTE INDIRECTLY INTO JANITORS SINK AND POSE NO RISK TO SANITARY SEWER SYSTEM I APPROVED THESE TRAPS AND THE PLUMBERS INSTALLATION THERE OF
03/16/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* OK TO COVER
03/14/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* CONNECTIONS MADE ON MENS AND WOMENS BATHROOMS OK CLEAN OUTS ADDED ON EWC'S ALONG EAST SIDE VENTS COMPLETED OK
03/13/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) MENS AND WOMENS PUBLIC RESTROOMS COPPER OK PRESSURE TEST 100# OK. OK TO INSULATE MAKE CHANGES IN ABS AS NOTED AND RETEST. 2) SINKS AND EWC ALONG EAST SIDE OK TO COVER
03/06/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) OVER HEAD COPPER PIPING INCLUDING DROPS TO BALL VALVES OK
2) CONDENSATE DRAINS REQUIRE CLEAN OUTS AT CHANGES OF DIRECTION 3) CHECK ALL HANGER REQUIREMENTS 4) BACK ROOM BATHROOM (143)_ DWV OK WATER TEST OK COPPER OK
02/26/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) COPPER OVER SALES FLOOR OK 2) 100# PRESSURE TEST OK 3) OK TO INSULATE
02/23/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) 1-15" ROOF DRAIN AND 3-10" ROOF DRAIN OK TO OUTSIDE BLDG WATER TEST OK CHANGE HUSKEE BANDS TO MISSION AND RE TEST 2) CONDENSATE DRAINS OK BUT NEED TO ADD DIRECTIONAL CLEANOUTS 3) INSP. REQUIREMENTS FOR ROOF DRAINS INSIDE COLUMNS
A) SAFTY EQUIPMENT - BODY HARNESS AND LANYOURD LADDER AIR TESTING EQUIPMENT FOR CONFINED SPACE ROPE ONE MAN FOR SPOTTING FLASHLIGHT
02/22/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
02/05/2001 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*
02/01/2001 PLUMBING - INTERMEDIATE Partial Approval GAS (MED PRESS) STUBOUT OF BLDG OK 60# AIR TEST OK
4 RAIN LEADERS UNDER SLAB OK WATER TEST OK