Permit: DP21-0218
Permit Details
Status:
Complete
Type:
Development Package
Address:
6335 E TANQUE VERDE RD
Address NEW:
6335 E TANQUE VERDE RD
Apply Date:
08/27/2021
Applicant:
Chris Leon
Description:
*Revision #1 started 4/11/24 (trash enclosure)* Site/Grading/Swppp - Wilmot Tower Self-storage.
Permit Reviews
Permit Number - DP21-0218
Permit Status: Complete
Permit Description: *Revision #1 started 4/11/24 (trash enclosure)* Site/Grading/Swppp - Wilmot Tower Self-storage.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/18/2022 | DEV PKG - RESUBMITTAL | 05/31/2022 | COMPLETED |
| 06/30/2022 | DEV PKG - RESUBMITTAL | 08/15/2022 | COMPLETED |
| 08/27/2021 | DEV PKG - OK TO SUBMIT | 09/03/2021 | COMPLETED |
| 09/14/2021 | DEV PKG - OK TO SUBMIT | 09/17/2021 | COMPLETED |
| 09/17/2021 | DEV PKG | 12/14/2021 | COMPLETED |
| 04/11/2024 | DEVELOPMENT PACKAGE NEW v.1 | 04/15/2024 | APPROVED |
Outstanding Inspections
Permit Status: Complete
Permit Number: DP21-0218
Permite Description: *Revision #1 started 4/11/24 (trash enclosure)* Site/Grading/Swppp - Wilmot Tower Self-storage.
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/02/2024 | SITE - Stormwater Final Inspection | N/A | Partial Pass | |
| 05/06/2024 | ENGR Engineering Final | N/A | Partial Pass | Partial pass this time. The following items still will need to be addressed prior to the final approval. 1) 6 inch vertical separation has not been provided on the north side of the office adjacent to the unloading zone. Area is 0 to 4 inches. 2) The elevator drain has been constructed only 4 feet away from the main doorway into the Storage Facility and will deposit water directly onto the sidewalk area on the west side of the building just north of the main pedestrian access point. This water needs to be directed to another location since it violates the code of no water being deposited directly onto pedestrian, access areas or sidewalks. |
| 12/08/2023 | ENGR Grading Final | N/A | Partial Pass | Trash enclosure, slab, and apron |
Completed Inspections
Permit Status: Complete
Permit Number: DP21-0218
Permit Description: *Revision #1 started 4/11/24 (trash enclosure)* Site/Grading/Swppp - Wilmot Tower Self-storage.
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/16/2024 | SITE - Stormwater Final Inspection | Passed | ||
| 05/30/2024 | PDSD Site/Engineering Division - Landscaping | Passed | ||
| 05/30/2024 | ENGR Engineering Final | Passed | ||
| 05/30/2024 | SITE - Stormwater Setup and Controls | Passed | ||
| 05/30/2024 | SITE - Stormwater Follow-up | Passed | ||
| 05/30/2024 | ENGR Grading Final | Passed |