Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: DP14-0246
Permit Details
Status:
Complete
Type:
Development Package
Address:
10146 E OLD VAIL RD
Address NEW:
10146 E OLD VAIL RD
Apply Date:
12/24/2014
Applicant:
Description:
GRADING/SWPPP- NW MEDICAL CENTER
Permit Reviews
Permit Number - DP14-0246
Permit Status: Complete
Permit Description: GRADING/SWPPP- NW MEDICAL CENTER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/27/2015 | RESUB - SITE and/or GRADING | 03/24/2015 | ACTIVE |
| 12/24/2014 | GRADING | 12/24/2014 | COMPLETED |
| 12/24/2014 | GRADING | 02/03/2015 | COMPLETED |
Completed Inspections
Permit Status: Complete
Permit Number: DP14-0246
Permit Description: GRADING/SWPPP- NW MEDICAL CENTER
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/27/2015 | PDSD Engineering Division Pre-Construction SITE | Passed | {Activity date: 04/27/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) SITE HAS A SWPPP THAT HAS BEEN IMPLEMENTED 2) MAINTAIN SEDIMENT CONTROLS THROUGHOUT CONSTRUCTION 3) INSTALL A CONCRETE/MATERIALS WASH OUT WHEN APPLICABLE 4) PERFORM AND DOCUMENT YOUR STORM WATER SELF INSPECTIONS PER YOUR SWPPP 5) CONTACT ENGINEERING PRIOR TO ANY UNDERGROUND STORM PIPE WORK OR FOR ANY SITE CHANGES/CONCERNS} |
|
| 11/20/2015 | SITE - Stormwater Follow-up | Passed | {Activity date: 11/20/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } ; {Activity date: 10/27/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 09/24/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - MAY NEED SUPPLEMENTAL SEDIMENT CONTROLS ALONG THE NORTH SIDE OF SITE IN ORDER TO COMPLY WITH YOUR SWPPP} ; {Activity date: 09/24/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 09/15/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) ENSURE STORM WATER SELF INSPECTIONS ARE PERFORMED AND DOCUMENTED PER YOUR SWPPP 2) SWEEP UP TRACKED SOIL AS NEEDED} ; {Activity date: 09/02/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 08/27/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) BASE OF CATCH BASIN POURED, RE-BAR SET AND FORMS CONSTRUCTED 2) RE-BAR = #4 AT 12" OC BOTH WAYS 3) SEDIMENT CONTROLS HAVE BEEN RE-ESTABLISHED AT THE NEW PERIMETER } ; {Activity date: 08/26/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) NO INSPECTIONS CALLED IN FOR MANHOLE CONSTRUCTION 2) NEED TO RE-ESTABLISH SEDIMENT CONTROLS AT PERIMETER OF SITE , TO INCLUDE AREA TO THE WEST WHERE CONSTRUCTION HAS EXPANDED BEYOND THE PROPETY LINE. 3) CALL IN FOR INSPECTION FOR ANY UNDERGROUND STORM WORK, APPROVALS WILL NOT BE GIVEN FOR SITE WORK NOT INSPECTED 4) PROVIDE A CERT LETTER FROM THE ENG OF RECORD PRIOR TO FINAL 5) ENSURE STORM WATER SELF INSPECTIONS} ; {Activity date: 08/17/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 07/17/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 06/24/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 06/02/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - INSTALL SEDIMENT CONTROLS AROUND TEMP. STOCKPILE} ; {Activity date: 05/14/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME ENSURE YOU INSTALL A CONCRETE/MATERIALS WASH OUT WHEN APPLICABLE} |
|
| 11/20/2015 | ENGR Grading Final | Passed | {Activity date: 11/20/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } | |
| 11/20/2015 | SITE - Stormwater Setup and Controls | Passed | {Activity date: 11/20/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } | |
| 12/07/2015 | SITE - Stormwater Final Inspection | Passed | {Activity date: 12/07/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - SUBMIT A NOTICE OF TERMINATION WITH ADEQ} ; {Activity date: 11/20/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) STABILIZE ALL DISTURBED AREAS ON SITE 2) SUBMIT A NOTICE OF TERMINATIONATION TO ADEQ.} |
|
| 12/10/2015 | PDSD Site/Engineering Division - Landscaping | Passed | {Activity date: 12/10/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } ; {Activity date: 12/07/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) INSTALL TRASH ENCLOSURE GATES 2) COMPLETE ADA PARKING CHANGES 3) INSTALL OVERHEAD POLES IN DRIVE AREA 4) COMPLETE LANDSCAPING 5) INSTALL BIKE PARKING PER PLAN} ; {Activity date: 11/20/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - COMPLETE LANDSCAPING} |
|
| 12/10/2015 | ENGR Engineering Final | Passed | {Activity date: 12/10/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } ; {Activity date: 12/07/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) INSTALL TRASH ENCLOSURE GATES 2) COMPLETE ADA PARKING CHANGES 3) INSTALL OVERHEAD POLES IN DRIVE AREA 4) COMPLETE LANDSCAPING 5) INSTALL BIKE PARKING PER PLAN} ; {Activity date: 11/20/2015; Status: Denied; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) COMPLETE SITE WORK TO INCLUDE LANDSCAPING AND STABILIZATION OF ALL DISTURBED AREAS 2) PROVIDE CERTIFICATION STATEMENT FROM THE ENG OF RECORD STATING THAT THE SITE/GRADING WAS CONSTRUCTED PER THE APPROVED PLANS. 3) PROVIDE AN AS-BUILT DRAWING 4) INSTALL BOLLARDS IN TRASH ENCLOSURE PER COT DEV. STD 6-01.0. 5) SUBMIT NOTICE OF TERMINATION WITH ADEQ} |