Parcel Search: 10706045A
Parcel Search
Parcel Attributes
| Parcel | 10706045A |
|---|---|
| Jurisdiction | Tucson, Pima County |
| Water Course | Street |
| City of Tucson Zoning | I-1 |
| Tucson Ward | Ward 3 |
| Tucson Registered Neighborhood | Flowing Wells |
| Major Street & Route | Arterial or Collector |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Address | |
| Parcel Attributes Issue? | |
Annexations & Original City Zoning (OCZ)
Date - 10/26/2026 1:33 a.m.
Total Number Of OZC Plans - (1)
Permits
Parcel Number - 10706045A
Date - 10/26/2026 1:33 a.m.
Total Number Of Permits - (8)
| Permit | Permit Status | Entered Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TR-UTL-0426-00662 | Inspections | 04/14/2026 | 10/19/2026 | Right-of-Way (ROW) - Utility | CONTINUATION PERMIT FOR TR-UTL-1025-01756 - NO CHANGES/UPDATES TO ORIGINAL PERMIT, WILL NEED THE SAME CONDITIONS: This franchise project involves the replacement of predominantly 5,182 feet of 1960's vintage 2" steel and 1087 feet of 1987-2021 PE8000/8100 main along with associated service lines. The project is being initiated by the City of Tucson under Job Number U-2024-033. The proposed improvements begin at the intersection of Flowing Wells and Miracle Mile and extend to the intersection of Grant Road. Scope of work includes roadway repaving, and sidewalks/ramps. COT project is scheduled to start during the first quarter of 2026. Due to the soil conditions within the project area, grade cuts will reach depths greater than 3 feet deep, placing the existing pipeline in direct conflict with the proposed grading. In total, the project will involve the installation of 6,063feet of 4" PE8400 main, 12 feet of 2" PE8400 and 14 feet of 1" PE8400 along with 1,590 feet of service line. The main installation method to be used is boring (5'x10' bore pits). 07/21/26- RENEW PERMIT FOR 90 DAYS AS OF 07/21/26 NEW EXPIRATION DATE IS 10/19/26 | |
| TR-UTL-1025-01756 | Complete | 10/07/2025 | 04/22/2026 | Right-of-Way (ROW) - Utility | This franchise project involves the replacement of predominantly 5,182 feet of 1960's vintage 2" steel and 1087 feet of 1987-2021 PE8000/8100 main along with associated service lines. The project is being initiated by the City of Tucson under Job Number U-2024-033. The proposed improvements begin at the intersection of Flowing Wells and Miracle Mile and extend to the intersection of Grant Road. Scope of work includes roadway repaving, and sidewalks/ramps. COT project is scheduled to start during the first quarter of 2026. Due to the soil conditions within the project area, grade cuts will reach depths greater than 3 feet deep, placing the existing pipeline in direct conflict with the proposed grading. In total, the project will involve the installation of 6,063feet of 4" PE8400 main, 12 feet of 2" PE8400 and 14 feet of 1" PE8400 along with 1,590 feet of service line. The main installation method to be used is boring (5'x10' bore pits). 01/15/26 - Request for 90 Day Renewal as of 01/22/2026 | |
| TS-PRM-1024-00442 | Inspections complete | 10/08/2024 | 11/17/2025 | Sign - Permanent | Install 2 non-lighted wall signs. | |
| T06OT01842 | Expired | 07/12/2006 | 07/28/2007 | SIGN | 11477 | |
| T08EL01365 | Final | 07/22/2008 | 03/01/2009 | ELECT | REPLACE: 2 200 DISCONNECTS W/NEW 200 DISCONNECTS | |
| T10OT01144 | Final | 05/25/2010 | 12/21/2010 | SIGN | 18412 | |
| T10OT01724 | Expired | 08/12/2010 | 10/04/2011 | SIGN | 18748 | |
| T15CM04343 | Expired | 06/26/2015 | 12/23/2015 | COMBO | RECONNECT ELECTRIC |
Code Enforcement
Parcel Number - 10706045A
Date - 10/26/2026 1:33 a.m.
Total Number Of Code Cases - 1
| Case Number | Case Status | Entered Date | Closed Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| T07FR01602 | Complete | 08/17/2007 | N/A | FIREINSP | A night/partial inspection was done by Inspector John Bieg on 8/13/07. |