Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SIGN PERMIT
Apply Date:
08/12/2010
Applicant:
ADDISIGNS INC
Description:
18748
Contractors:
  • ADDISIGNS INC

Outstanding Inspections

Permit Status: Expired
Permit Number: T10OT01724
Permite Description: 18748
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
04/07/2011 SIGN ELECTRIC N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NM CABLE AND CONDUCTOR IN DETERIORATED CONDITION-NM NOT FOR WET LOCATION
2) BURIAL DEPTH TO BE PER 300.5
3) PROTECT CONDUCTOR FROM SHARP EDGES 300.4 AND USE APPROVED FITTINGS
4) CONDUCTOR TO AMPACITY OF CIRCUIT
5) HAND HOLE NOT LARGE ENOUGH TO WORK IN
6) BOND POLE AND BOX
7) DISCONNECT ON WALL NOT INSTALLED TO CODE-WHAT IS DISCONNECT FOR ?
8) VERIFY SIGN CIRCUIT FOR 600.5

Completed Inspections

Permit Status: Expired
Permit Number: T10OT01724
Permit Description: 18748
Total Completed Inspections - 3
Date Description Inspector Results Comments
08/19/2010 SIGN SITE REVIEW JYBARRA Approved
10/21/2010 SIGN EXCAVATION JYBARRA Approved
04/06/2011 SIGN INSPECTION JYBARRA Approved

Documents

File Name Document Type  
FWELLS2.JPG SIGNS VIEW
None SIGNS VIEW