Parcel Search: 124182690
Parcel Search
Parcel Attributes
| Parcel | 124182690 |
|---|---|
| Jurisdiction | Tucson, Pima County |
| City of Tucson Zoning | I-1 |
| Tucson Ward | Ward 5 |
| Tucson Registered Neighborhood | Millville |
| Major Street & Route | Gateway Route |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Address | |
| Parcel Attributes Issue? | |
Annexations & Original City Zoning (OCZ)
Date - 10/24/2026 5:50 a.m.
Total Number Of OZC Plans - (1)
| Plan | Description | Annexation Ordinance | Effective Date | OCZ Ordinance |
|---|---|---|---|---|
| 3/4 Mile East To Campbell Avenue | 486 | 07/13/1919 |
Permits
Parcel Number - 124182690
Date - 10/24/2026 5:50 a.m.
Total Number Of Permits - (7)
| Permit | Permit Status | Entered Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TR-UTL-0323-01067 | Complete | 03/10/2023 | 06/12/2023 | Right-of-Way (ROW) - Utility | 25ft BELL HOLE | |
| T22CM02151 | Expired | 03/23/2022 | 09/28/2022 | Commercial Building | NEW GAS PIPING TO ACCOMMODATE RETORT AT AVENIDA CREMATORY. PIONER CONTACT: DANIEL 5207304734 | |
| TC-COM-1026-01658 | Needs resubmittal | 10/06/2026 | N/A | Commercial Building | Arrived onsite to inspect existing gas lines found that they have been operating with a undersized system that was installed without permit or inspection being performed checked btu count and got linear footage for system. Needs to be replaced to be up to code standards will get info together and submit estimate for required Work to be performed took pics of units have a total of 140 ft from meter to furthest furnace We will run new gas pipe from meter to 2 crematory pits and 1 suspended heater Has a combined total of 5.2 million btu per hr. count We will supply and install new gas piping to proper size for system Includes new isolation valves at take off and at units Pics of all work performed will be provided Includes permit and inspection of work performed Please note that if any cc plumbing doesn’t meet code additional charge will occur Gas line will be suspended from roof using clevis hangers for support Once work is completed will pump system up to 15 psi to check for leaks Estimate includes any code upgrades pertaining to gas installation only New gas line comes with 2 yr warranty from ram Gas line to be run in 1 1/2 1 1/4 and 1” black steel | |
| TC-COM-1026-01714 | Submitted - online | 10/19/2026 | N/A | Commercial Building | Arrived onsite to inspect existing gas lines found that they have been operating with a undersized system Without permit or inspection being performed checked btu count and got linear footage for system Needs to be replaced to be up to code standards will get info together and submit estimate for required Work to be performed took pics of units have a total of 140 ft from meter to furthest furnace | |
| T16EX01259 | Final | 04/13/2016 | 06/12/2016 | EXCAV | Tie point NE of 1316 21st begin 10' bore/trench heading N and then turn W trench 25' Turn S with a 3' side walk bore and on to private property | |
| T16TC00886 | Expired | 04/13/2016 | N/A | BARRICAD | Tie point NE of 1316 21st begin 10' bore/trench heading N and then turn W trench 25' Turn S with a 3' side walk bore and on to private property | |
| T22RW00960 | Final | 03/15/2022 | 05/01/2022 | ROW | WO#4399780 (1) 4' X 20' TRENCH IN FRONT DIRT/CONCRETE SIDEWALK TO INSTALL NEW GAS SERVICE LINE. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. ** PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL. |
Code Enforcement
Parcel Number - 124182690
Date - 10/24/2026 5:50 a.m.
Total Number Of Code Cases - 2
| Case Number | Case Status | Entered Date | Closed Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| CE-VIO0926-03738 | Notice of violation | 09/08/2026 | N/A | Code Enforcement Case | ZCOM/ illegal crematorium | |
| T05FR00586 | Complete | 05/02/2005 | N/A | FIREINSP | Inspection |