Permit: T21CM09453

Parcel: 11620637A


Addresses:

165 S LINDA AV


Inspection Status: Re-inspection required

Inspection History: COT - HCPL - Plumbing Intermediate 

Permit Number - T21CM09453

Inspection Description - COT - HCPL - Plumbing Intermediate 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
01/22/2026 COT - HCPL - Plumbing Intermediate  Re-inspection required 1/22/26: nail plates required for electrical and plumbing that come within 1 1/4" from face of 2x, over notched studs both at bearing and non bearing walls must be properly fixed and be addressed prior to next inspection, fire caulking required at all penetrations through top plate and vapor barrier, Properly secure nm cable throughout, receptacle spacing not per approved plans not per code (bedrooms and living rooms) staples required throughout at nm cables coming out of box. units inspected were (402, 426, 428,413,414,415 receptacle at bathroom, 416,418) notes are the same for all.
02/06/2026 COT - HCPL - Plumbing Intermediate  Partial Pass 2/6/26: MEP 4TH FLOOR AREA C 427,425,424,401,408,407,405, 406,404,427,425,424,404,426,428,412,413,414,415,416, 418,417, 419,420
02/12/2026 COT - HCPL - Plumbing Intermediate  Partial Pass 2/12/26:PLUMBING ABOVE CEILING APPROVED AT T.I RESTAURANTS FIRST FLOOR SOUTH BUILDING SE CORNER
03/04/2025 COT - HCPL - Plumbing Intermediate  Partial Pass Plumbing in units 242, 246, 247, 248, 257, 259.
05/23/2025 COT - HCPL - Plumbing Intermediate  Partial Pass Section C. 4th floor. 412, 408,407,406,405,404,403,402,401,424, 425,427. DWV and domestic water on test. Okay to proceed progress areas. 5/23/2025
06/17/2024 COT - HCPL - Plumbing Intermediate  Partial Pass New sewer line, 8” and 6” laterals.
06/20/2025 COT - HCPL - Plumbing Intermediate  Partial Pass 6-20-25: grease interceptor located at southeast side verified per plans. Okay to continue with construction
10/23/2024 COT - HCPL - Plumbing Intermediate  Partial Pass Domestic water lines at levels 1 - 3. Under hydro test at 140 psi. Ok to drop pressure in lines.
10/24/2024 COT - HCPL - Plumbing Intermediate  Partial Pass Level #1, in wall plumbing in room units; S133, S135, S138, S139, S140, S157, S158, S160.
10/29/2024 COT - HCPL - Plumbing Intermediate  Partial Pass Level #1, in wall plumbing in room units,S141, S143, S144, S148, S159. ok to insulate and cover walls.
12/12/2023 COT - HCPL - Plumbing Intermediate  Partial Pass Information only..plans for plumbing changes.