Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T21CM09453

Parcel: 11620637A


Addresses:

165 S LINDA AV

Inspection Status: Partial Pass

Inspection History: COT - HCBU - Preslab  

Date Description Inspector Results Comments
01/05/2024 COT - HCBU - Preslab   Partial Pass Podium, Placement,#8, bottom rebar mat. Ensure stirrups are properly placed in beam areas.
01/22/2024 COT - HCBU - Preslab   Not Ready Contractor cancelled due to inclement weather.
02/01/2024 COT - HCBU - Preslab   Partial Pass Podium at placement #10, bottom mat. Ok to place concrete in progress areas
02/14/2024 COT - HCBU - Preslab   Partial Pass Slab area #10. Ok to place concrete in progress areas.
07/06/2023 COT - HCBU - Preslab   Partial Pass This inspection is for excavation/layout rebar for concrete column footings at HL: H/11 (F2), I/11 (F2), J/11 (F4). Ok to place concrete in progress areas.
07/10/2023 COT - HCBU - Preslab   Partial Pass Area A, Elevator #2 footings. Ok to place concrete in progress areas. Column footings (F2, F4) at GL: J/8, L/1O, M/10, L/12, I/12, H/12, G/11, K/10.
09/20/2023 COT - HCBU - Preslab   Partial Pass Plumbing underground in Areas A & B; 4” waste lines. Ok to cover progress areas.
10/12/2023 COT - HCBU - Preslab   Partial Pass North west portion of Areas A & B. Ok to place concrete in progress areas.
11/03/2023 COT - HCBU - Preslab   Partial Pass Level #1, Area B: Top and bottom rebar mat. Followed plans are per Asst Superintendent Keven, checked as closely as possible. Ok to place concrete in progress areas.
11/06/2023 COT - HCBU - Preslab   Partial Pass Area B, pour #1, top and bottom rebar mesh in place. Ok to place concrete in progress areas.
11/09/2023 COT - HCBU - Preslab   Not Ready Contractor cancelled. Will reschedule for 13 November
11/13/2023 COT - HCBU - Preslab   Partial Pass Area B placement #2 bottom mat (areas except for West side of slab).
11/16/2023 COT - HCBU - Preslab   Partial Pass Area B - A, placement #2; top rebar mat and hold downs. Ok to place concrete in progress areas.
11/17/2023 COT - HCBU - Preslab   Partial Pass Podium area, placements #3; bottom mat and hold-downs. Ensure all add,on rebars are properly tied down and all hold downs are in place.
11/28/2023 COT - HCBU - Preslab   Partial Pass Level #1, concrete placement #4, bottom mat of double mat rebar system. Ensure hold downs are in place as per plans. Ok to place concrete in progress areas.
11/29/2023 COT - HCBU - Preslab   Partial Pass Area A, Placement #4; Podium area. Ok to place concrete in progress areas.
11/30/2023 COT - HCBU - Preslab   Partial Pass Slab on grade for placement #6. Ok to place concrete in progress areas.
12/07/2023 COT - HCBU - Preslab   Partial Pass Slab areas A and B, pour #5 bottom mat.
12/14/2023 COT - HCBU - Preslab   Partial Pass Bottom mat for Area A/B, pour #6.
12/19/2023 COT - HCBU - Preslab   Partial Pass Podium area,double Matt for placement,#6. Ok to place concrete in progress areas.
12/21/2023 COT - HCBU - Preslab   Partial Pass Podium area at placement #6; information only.
12/28/2023 COT - HCBU - Preslab   Partial Pass Podium, placement #7 in areas C & D. Ok to place concrete in progress areas.