Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T17CM00004
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/29/2019 | REINFORCED MASONRY PRE-GROUT | Approved | ||
12/19/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Stairwell A masonry top out | |
12/18/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 12 floor West side wall on the stairwell | |
12/17/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 12th floor north east stairwell Southwall | |
12/14/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Stairwell E north side top out | |
12/13/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | MASONRY WALLS ON ROOF AT STAIRWAY NE OK TO GROUT | |
12/13/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Eastside elevator wall | |
12/06/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | On roof, masonry for stairway A (NE corner) ok to grout to 4’. | |
12/05/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Masonry east side of elevator core to 4’ and restroom on roof to top OK to grout. | |
12/03/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | On roof pool restroom East & South walls first lift ok to grout | |
11/30/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Level #B-1; Elevator wall, topped-out. Ok to grout progress areas. | |
11/28/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Main elevator levels B1 & B2 masonry walls OK to top | |
11/21/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Stairwell B on roof all masonry OK to grout | |
11/20/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | Work is not complete enough to inspect. | |
11/02/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | East transformer area; CMU walls at 8'- 12', top out. Ok to place grout. | |
11/01/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Entry door areas (elevators) at Levels #B-1 & B-2. Level #1, retail elevator at 8' - 11' 4". OK to place grout in progress areas | |
10/30/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Retail elevator level one add rebar as required (32 inches on center ) then OK to grout. | |
10/26/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Level B1 stairway D ok to grout to top of wall | |
10/25/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | East ramp wall ok to top of wall Transformer enclosure ok to 4’ |
|
08/16/2018 | REINFORCED MASONRY PRE-GROUT | Cancelled | ||
08/15/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SAME AS 8/13 | |
08/15/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | ||
08/13/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LEVEL 1 RAMP WALLS WEST, EAST, SOUTH OK TO TOP | |
08/09/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LEVEL 1 RAMP EAST SIDE OK TO 4' | |
08/08/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LEVEL 1 EAST, WEST AND SOUTH SIDES OF RAMP WALLS OK TO 4' | |
08/07/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LEVEL 1 LOADING ROOM AND TRASH ROOM OK TO GROUT TO TOW | |
08/01/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LEVEL B-1, STAIRWELL "C" AT 8'4" - 12' 4". OK TO GROUT PROGRESS AREA. | |
07/25/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LEVEL #1, TRASH ROOM, LOADING AREA; RAMP AT 3' - 5'4". OK TO GROUT. | |
07/23/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LEVEL #B-1, STAIRWELL "C", PUMP ROOM AT 4' - 8'; STAIRWELL "D" AT 8' - 12"; SOUTHEAST AIR SHAFT AT 4'-8'. OK TO GROUT PROGRESS AREAS. | |
07/20/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LEVEL B-1, FIRE PUMP ROOM AT 4' - 8'4". OK TO GROUT. | |
07/18/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | BASEMENT LEVEL #B-2, STAIRWELL "C" WITH STORAGE AREA; STAIRWELL : "D" WITH STORAGE AREA - ALL AT 4' - 7'4"; ELEVATOR LOBBY WALL AT 0' - 4'. BASEMENT LOBBY AT 0' - 4'; STAIRWELL "C" WITH FIRE PUMP ROOM AT 0' - 4'. OK TO GROUT PROGRESS AREAS. | |
07/16/2018 | REINFORCED MASONRY PRE-GROUT | Cancelled | COTRACTOR CANCELLED - WORK INCOMPLETE. | |
07/13/2018 | REINFORCED MASONRY PRE-GROUT | Cancelled | CONTRACTOR CANCELLED, | |
07/12/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LEVEL #B-2, STAIRWELL D AND C AT 0' - 4'; NORTHWEST AND SOUTHEAST AIR SHAFTS (B-2). B-1 STAIRWELL D; SOUTHEAST AIR SHAFT (0' - 4'). OK TO GROUT PROGRESS AREAS. | |
07/09/2018 | REINFORCED MASONRY PRE-GROUT | Cancelled |