Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T21CM04121
Parcel: 12404098A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM04121
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/16/2021 MGAYOSS1 DESIGN PROFESSIONAL REVIEW Approved DATE: July 11, 2021
FROM: Rick Gonzalez, Architect (#26992)
COT On-Call Design Professional
RE: CD Review, Aspire 2,
Chase Bank T.I., T21CM04121

I have reviewed the Chase Bank Tenant Improvement Construction Documents
submitted June 2021 for the purpose of determining conformance with the Design
Package of the IID. I have checked the submittal against the Main Gate District
(MGD) Ordinance Requirements relative to Section C-19, Design Standards under
procedure described in Section B-2.d.
Submittal Requirements Status
1. Lighting: Conforms to
minimize light glare and trespass, conserve energy, the approved
promote safety and security, full cut-off fixtures, Design Package
concealed from public right-of-way view
2. Building Materials and Colors: Conforms to
chosen for tactile effects, contrast... like rough to the approved
smooth, vertical patterns vs. horizontal. Etc., integral Design Package
colors, visual and physical permanence in the Sonoran
Desert. Localizing effect, ambiance, coherence with the
neighborhood. Facades on public streets or open space:
Use high quality materials such as: brick, stone, pre-cast
concrete, cast stone, CMU's. Brick panels... Architectural
metals... panels, sheets... with expressed seams, cuts,
stamps, casts, or ornamental panels. Glass/glass block...
Modular panels: EIFS, stucco, but less than 25% of total
facade at the base along public streets. At lower floors
adjacent to street frontage, respond to pedestrian ways...
using quality scale, texture color, detail. Material
combinations reinforce architectural scaling requirements.
Reflects tradition of U of A, COT, adjacent historic
neighborhoods. Use accent colors consistently throughout:
signs, architectural features, lighting, window/door frames,
and accent walls. Avoid glare reflective producing
materials.
3. Architectural Elements and Features: Conforms to
Balconies, outdoor stairs, ornaments and surface details the approved
such as screening, cladding and fenestration shall be Design Package
provided to enhance the architectural style of the
building. No balconies allowed in group dwellings.
Consider appropriate use, scale, proportion, texture
Carefully integrate in the concept design. Clear visual
distinction between the ground and upper floors.
Arcades, when used, place along south and west facades,
unless along Park Avenue. Construct out of wood, brick,
canvas, metal, stone or concrete. Street facing facades:
20' maximum single plane without architectural detailing.
Outdoor vending and gathering areas encouraged.
Delineate with hardscape, grade change, or vegetation.
4. Building Articulation:
3 consecutive street facing facade areas: same paint Conforms to
or method of articulation. Articulate facades at entries the approved
between retail spaces for patio and outside engagement. Design Package
Building long than 85' – articulate each 85' to appear as
separate buildings along a front property line. Building
corners – add articulation to emphasize and promote
gathering (e.g. roof/facade higher at corner).
Local public art encouraged (e.g. sculpture art).
5. Doors Conforms to
shade and weather protection at entries, clear the approved
identification, safe, secure, universally accessible. Design Package
Storefronts – provide awnings, canopies for shade,
color, and material variation; integrate with sidewalk
design and treatment. Clearly identifiable “front door”
at each facade on a major street. Residential Units -
provide separate street access, residential scale,
demarcated by awning, stoop or recess.
6. Windows and Glazing: Conforms to
low e, visual connection through either side. Size, the approved
proportion, pattern relates to unit type/layout. Design Package
Reinforces facade patterns of scale and variety.
property and the proposed use(s). Mixed usesuses
a variety of ratios of clear to opaque surfaces
(i.e. glass to wall) and on commercial greater glass
to wall.
7. Building Facades: Conforms to
Base to have at least two of the following... the approved
trellis or vertical garden with 50% vegetation. Design Package.
Local artist Artwork (e,g, public mural, custom
panel, small retail space (50 sf plus GFA, coffee
cart, kiosk, etc.). Outdoor dining, gathering patio,
delineated by low wall, fence, planter, change of
elevation, or other buffers. Distinctive Lighting.
Shade structure, changes of plane such as indentations,
textures, or accent materials. Windows – 75% minimum
visible light on each side of window. Window displays
or visible activity on ground floor.
8. Streetscape: N/A
along Speedway and Euclid Avenue, design to
promote community.
General Comments:
None
Based on review of the CD Plan Set, the plans conform to the Approved Design
Package and Chase Modification 2 Approved Plans dated 6-1-21. The plans do not
deviate from the approved Design Package. Therefore, I recommend approval
as submitted.
07/20/2021 SAFEBUILT 2ND PARTY REVIEW REVIEW Approved
08/02/2021 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed
08/02/2021 STEVE SHIELDS ZONING REVIEW Approved