Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T20CM07489
Review Name: COMMERCIAL - NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/16/2020 | ROBERT SHERRY | WATER | REVIEW | Reqs Change | Provide the missing plumbing plans. |
| 11/16/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Provide the missing plumbing plans. |
| 11/16/2020 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Provide the missing mechanical plans. |
| 11/19/2020 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Define the AHJ on the cover sheet for fire alarm, fire sprinkler and fire final inspections. |
| 11/23/2020 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. 1. Provide full compliance with the 2012 Tucson/Pima County Outdoor Lighting Code. 2. Provide full compliance with the 2018 IECC for the lighting. Do not confuse the IECC with the Outdoor Lighting Code. 3. Provide GFI protected receptacles for the kitchen and food prep areas. NEC 210.8B(2) Ref; 2018 IBC sec, 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements. 2012 Tucson/Pima County Outdoor Lighting Code. |
| 11/24/2020 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 11/24/2020 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheets G101 and G102; Project Data (Codes): Please revise the ICC/ANSI A117.1 to the 2009 Edition. 2. Sheet G102; Kitchen Code Plan: A single exit sign is indicated on this plan. Since a minimum of two exits are required, please indicate on the plan the location of the exit sign at that second exit. 3. Sheet G102; Code Review: Please indicate the new SF added (including dining and covered area) to the existing building. In addition, indicate the existing building SF, along with the total building SF. 4. Sheet A101; General Notes: Note 5 references Sheet A118 for Wall Types. Please revise that reference. 5. Sheet A101; New Floor Plan: An enlarged plan indicator at the Kitchen references 1/A900. Please revise that reference. 6. Sheet A201; Reflected Ceiling Plan: Please indicate the exit sign fixtures on this plan. 7. Sheet A700; Wall Types: On Wall Types E1 and E2, please indicate the gauge of the metal studs. 8. General: The valuation needs to be revised. Please indicate the valuation for each project separately. 9. General: Please provide written responses to all review comments. |
| 12/17/2020 | NICHOLAS ROSS | ZONING | REVIEW | Passed | |
| 12/17/2020 | NROSS1 | ENGINEERING | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/21/2020 | PCAMARE1 | OUT TO CUSTOMER | Completed |