Permit Number: T13CM04783
Parcel: 12314138A

Address:
1724 N 1ST AV

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T13CM04783
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/06/2013 MICHAEL ST. PAUL ZONING REVIEW Approved
08/06/2013 LOREN MAKUS ENGINEERING REVIEW Approved
09/04/2013 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
09/04/2013 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied Provide an exhaust fan for the restroom. The fan shall run whenever the A/C unit is delivering air to the restroom.
09/04/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Provide cleanouts sized for the nominal pipe size.
2. Provide a temperature mixing valve for the lavatory listed to ASSE 1070.
3. Provide a shower valve listed to ASSE 1016.
4. The maximum water flow for the lavatory is 0.50 GPM.
09/04/2013 ROBERT SHERRY WATER REVIEW Passed
09/06/2013 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
09/06/2013 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
09/09/2013 CPIERCE1 WWM REVIEW Needs Review
09/09/2013 KEN BROUILLETTE FIRE REVIEW Approv-Cond PROVIDE ADDRESSING AND FIRE EXTINGUISHER