Permit Number: T10CM00917
Parcel: 12620001C

Address:
3400 E ZOO CT

Review Status: Completed

Review Details: RESUBMITTAL - TI ALL

Permit Number - T10CM00917
Review Name: RESUBMITTAL - TI ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/12/2010 DAVE MANN FIRE REVIEW Denied Fire Comments:

Please provide a comment letter describing how each comment has been addressed.

Provide the following data on the site plans. Comments based on OC201.

Please indicate existing fire hydrant location(s), with dimensions to buildings and/or property lines. Refer to City of Tucson amendments to the 2006 International Fire Code (section 508) for spacing and location requirements. The new hydrant is too far from the back of the elephant house and the the Ranger Station if it is not sprinklered. The distance is measured around the buiding. Not as the crow flies.
07/12/2010 RONALD BROWN ADA REVIEW Approved
07/13/2010 GERRY KOZIOL WWM REVIEW Passed
07/13/2010 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Reid Park Zoo Elephant Exhibit
T10CM00917
Building Plan (1st Review)

TRANSMITTAL DATE: April 12, 2010

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the building plan was in compliance with the approved site plan.. Please submit two copies of the approved and stamped site plan with the next building plan submittal.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\grading\t10cm00802.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:
07/16/2010 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
07/23/2010 ROBERT SHERRY WATER REVIEW Approved
07/23/2010 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Comment not addressed; drawings remain unchanged. Show how locating a floor sink (P-12, installed per detail 220) along with a floor-mounted condensate drain pipe in the service entrance area walkway will not interfere with access to the LSS equipment area. Reference: Section 309.0, UPC 2006.
2. Comment not resolved; the proposed design establishes a direct connection between the potable water and the sewer-connected waste which is not allowed per Section 603.3.5, UPC 2006. Provide air-gap separation between the potable water supply and the flushing header, the manual water make-up, and the float-operated water fill in the settling chamber. Reference: Section 603.3.5, UPC 2006.
07/23/2010 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
07/26/2010 PAUL MACHADO ENGINEERING REVIEW Approved
08/06/2010 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/10/2010 CPIERCE1 OUT TO CUSTOMER Completed
09/10/2010 SUE REEVES REJECT SHELF Completed