Permit Number: T09CM00182
Parcel: 14122004L

Address:
8755 S RITA RD

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T09CM00182
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/11/2009 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved 1. PREVIOUS NOTES 2 AND 3 DID NOT GET RESOLVED. PLEASE ADDRESS THOSE ISSUES.
03/23/2009 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
03/23/2009 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Correct the size of the new rain leader shown on sheet P102. An 8" rain leader is being connected to a new 12" rain leader at column line G,-4. Reference: Sections 311.5 and 316.4.1, UPC 2006.
2. Comment not resolved. Clarify how the roof drains and overflow roof drains along column lines E, J, L, and Q, are accommodating different roof areas. Reference: Section 103.2.3, UPC 2006.
3. Sheet C1 (grading and drainage plan) cannot be approved because it is labeled as "Preliminary - Not For Construction".
4. Provide cleanouts for each rain drain service lateral (detail 9/C501). Reference: Sections 707.4 and 1101.12.2, UPC 2006.
5. The maximum distance between a cleanout and a manhole in a storm sewer shall be 100 feet. Reference: Sections 719.2, 719.4, and 1101.12.1, UPC 2006.
6. Revise the size and slope of the storm sewer per Section 1106.2, UPC 2006 or provide calculations to show that the design of the storm sewer can accommodate the water flow from a storm with a 60-minute duration and a 100-year return period (0.031 GPM/ square foot of projected roof area).
03/24/2009 TERRY STEVENS ZONING REVIEW Denied 03/24/2009

Development Services Department
Zoning Review Section

Terry Stevens
Lead Planner

Comments:

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the building plan was in compliance with the approved development plan. Please submit two copies of the approved and stamped development, landscape, and NPPO plans with the next building plan submittal.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved site/development plan. Additional comments may be forthcoming.
03/27/2009 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/03/2009 CPIERCE1 OUT TO CUSTOMER Completed
04/03/2009 SUE REEVES REJECT SHELF Completed