Plan Number: S06-031
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S06-031
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/23/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Approved
05/21/2007 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, Engineering and Floodplain Review, 05/21/2007

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Sierra Morado Unit 4
S06-031, T15S, R15E, SECTION 01

RECEIVED: Final Plat and Assurances on December 06, 2006

The subject project has been reviewed. The Final Plat is acceptable and it is hereby recommended for approval pertaining to Engineering and Floodplain Review.

The assurances shall be recommended for approval once the assurances are revised to include the following information:

1. Revise the description of Common Area "B" through out the Assurance document to match the Final Plat. This comment was made previously but it has not been addressed satisfactorily. The Final Plat describes Common Area "B" as (Recreation, Access Lanes, Parking and Utilities). The assurances describe Common Area "B" as: (Drainage, Recreation and Utilities).
2. Include the "Trust Agreement" in the Assurances Package.

Submit with the Final Plat Mylar an original assurance document that has been revised in accordance with the comments above.

RESUBMITTAL REQUIRED: Final Plat Mylar and revised Assurances
05/21/2007 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-031 SIERRA MORADO UNIT 4/REVISED FINAL PLAT
DATE: MAY 18, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


Delete or explain “Together with portions of common Area “B” and “Sierra Morado Unit 2 West, per Book 61 Maps & Plats, Page 49” on all Title Blocks.

Change Creosote Ridge Land to Way.

Delete parcel codes on pgs. 12, 13 & 14.







jg
05/21/2007 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S06-031 SIERRA MORADO UNIT4/REVISED FINAL PLAT
DATE: May 23, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

APPROVED ON CONDITION THAT THE FOLLOWING IS CORRECTED ON FINAL PLAT:

CHANGE CREOSOTE RIDGE LANE TO WAY.
DELETE PARCEL CODES ON PGS. 12, 13, & 14.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***



jg
05/24/2007 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approv-Cond SUBJECT: SIERRA MORADO,UNIT 3 & 4

S06-056 & S06-031



Tucson Electric Power Co. (TEP) conditionally approves the final plats
submitted for review through the City of Tucson on April 23, 2007.



TEP's easement requirements have been shown on copies of the plats sent
directly to TEP for review on May 23, 2007 and by email today. These
easements are acceptable to TEP and we can approve the plats.



Should you have any questions, please contact me at (520) 917-8745.


Liza Castillo, Right of Way Agent
Land Management
Tucson Electric Power Co.
Unisource Energy Gas & Unisource Energy Electric
PH: (520) 917-8745
RightFax: (520) 545-1416
lcastillo@tep.com <mailto:lcastillo@tep.com>
05/24/2007 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approv-Cond -----Original Message-----
From: Castillo, Liza
Sent: Tuesday, June 05, 2007 10:06 AM
To: 'City of Tucson - CDRC'
Cc: 'Stucki, Ryan'
Subject: FW: SIERRA MORADO,UNIT 3 & 4 - S06-056 & S06-031


SUBJECT: SIERRA MORADO,UNIT 3 & 4

S06-056 & S06-031



Tucson Electric Power Co. (TEP) approves the final plats, all easement
requirements have been met.



Should you have any questions, please contact me at (520) 917-8745.



Liza Castillo, Right of Way Agent
Land Management
Tucson Electric Power Co.
Unisource Energy Gas & Unisource Energy Electric
PH: (520) 917-8745
RightFax: (520) 545-1416
lcastillo@tep.com <mailto:lcastillo@tep.com>
05/31/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 31, 2007
Ryan R. Stucki PE
Stantec Consulting
201 North Bonita
Tucson, Arizona 85745

Subject: S06-031 Sierra Morado Unit 4 Final Plat

Dear Ryan:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents:

(2) Title reports current within the last thirty (30) days.
(1) Executed Final Plat Double Matte Océ or Photo Mylar.
(1) * Check in the amount of $8.50 per plat page for Mayor & Council distribution made payable to the local print company of your choice or provide an account number to charge.
(1) * Check in the amount of $55.00 per plat page for recorded plat distribution made payable to the local print company of your choice or provide an account number to charge.
(1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page.
(1) Executed and notarized CC&R's document (if applicable).

*Please do not combine the checks for the printing charges. They are processed at different times and require separate checks. An account number is also acceptable and you can include this information on your transmittal sheet when submitting the above listed items.

Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval.

PRIOR TO SUBMITTING THE MYLARS TO THE CITY OF TUCSON CDRC OFFICE, TEP MUST REVIEW AND PROVIDE WRITTEN DOCUMENTATION (E-MAIL IS SUFFICENT) THAT CONDITIONS OF APPROVAL HAVE BEEN MET ON THE FINAL PLAT MYLARS.

Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 750-7470