Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP22-0091
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 08/29/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Reqs Change | DP22-0091 Comments: 1. On Sheet 2- Add "Per P.A.G. standard 207" to Keynote No.9, -New Curb Access Ramp. 2. Sight Visibility Triangle at the ingress/ egress entrance/ exit onto Granada is incorrect. Please correct the "Near Side" SVT. Granada Ave is a collector street. SVT near side length needs to be 265 Ft. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
| 09/07/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: City Center Development Development Package (2nd Review) DP22-0091 – C9-21-11 TRANSMITTAL DATE: September 7, 2022 DUE DATE: September 14, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is April 14, 2023. CONTENT REQUIREMENTS 1. This comment was not fully addressed. The case number was not provided on sheets 9 – 24. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0091, adjacent to the title block on all sheets. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2. A hold has been put on T22CM03719, 3720, 3721, 3722, 3723, 3724 & 3725 until lot combination documentation has been provided. COMMENT: 2-06.4.9.A – As this site is made up of five (5) parcels: 116-19-027A, 116-19-028A, 116-19-033A, 116-19-175B & 116-19-378B, a lot combination is required. Provide a copy of the approved Pima County Combo Request form with the next submittal. 3. This comment was not addressed correctly. The angle called out on the detail is 32 degrees but you comment response states that the angled parking is to be 30 degrees. COMMENT: 2-06.4.9.H.5.a – Provide a detail for the angled vehicle parking that demonstrate all dimensions shown on Figure 7.4.6-A. 4. COMMENT: 2-06.4.9.H.5.a – The accessible vehicle parking space north of Bldg 8 does not have an access aisle. 5. This comment was not fully addressed. As you are proposing a TSMR to substitute striping for the sidewalk along the east side of Office & Fitness Center TSMR will need to be approved prior to approval of this DP. If approved provide the TSMR case number adjacent to the title block on all sheets and provide a general note stating the case number, date of approval, what was modified, and if applicable any conditions of approval. COMMENT: 2-06.4.9.R – Per TSM Section 7-01.4.1.B A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located, Provide a sidewalk at the following areas: a. Along the east side of Office & Fitness Center. 6. COMMENT: 2-06.4.9.R – Clearly demonstrate that the minimum sidewalk width, 4’-0” is maintained for the sidewalk located between the access ramp and the northwest corner of Bldg 6. 7. This comment was not addressed. COMMENT: 2-06.4.9.U – It does not appear that the plan matches the Rezoning PDP dated 7-22-21 Provide written documentation form John Beall that this plan matches. 8. This comment was not addressed. Rezoning condition 13 you state “Family barbeque and picnic areas have been noted, Zoning acknowledges that Keynote 8 calls out an area but not detail as to what is proposed. Rezoning condition 16 you state “The gate at the southeast corner of the site providing access to Franklin Street will be a keyed gated ingress/egress for emergency vehicles” but there is nothing on the plan show this requirement. Rezoning condition 18 you state “There is currently open access to the El Paso & Southwestern Greenway. A defined walkway has also been added at the northeast corner of building 5”, but no walkway providing a secure connection to the greenway is shown on the plan. COMMENT: 2-06.4.9.U – Clearly demonstrate that the requirements of Rezoning conditions 13, 16, 18 & 20 are met. A Design Professional review has been added to the Development Package review to ensure that all Rezoning conditions have been addressed correctly. If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 09/12/2022 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Reqs Change | (View in DOCUMENTS section of PRO, titled "ADOT review comments, second submittal, 09.09.22") Email from: Jay Gomes <jgomes@azdot.gov> To: CDRC Sept. 9, 2022 Attached you will find correspondence as it relates to review comments on the aforementioned development traffic study. The TIS should be updated to reflect the comments. There are no anticipated Off-site improvements in ADOT R/W as a result of this TIS. Let me know if you have any questions or concerns regarding this item. Respectfully, James Gomes, Jr. Southern Regional Traffic Engineer ADOT 1221 S. 2nd Ave. Tucson, Az 85713 (520)388-4231 Office (520)603-9826 Cell www.azdot.gov |
| 09/15/2022 | SBEASLE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Approved | email from: Nicholas Jordan To: CDRC 09/15/2022 Pima County Addressing Approved DP22-0091 City Center Development. Nicholas Jordan Site Review Project Manager - Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-9623 |
| 09/19/2022 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 09/22/2022 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/Native Plant Preservation Section ACTIVITY NO: DP22-0091 v2 Address: 475 N Granada Ave Zoning: C-2 Existing Use: Travellers’ Accomodations Proposed Use: Multi-family TRANSMITTAL DATE: September 22, 2022 DUE DATE: September 14, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. 1. This comment was not adequately addressed – It also needs to on the grading plan - Please add a detail to show depressed landscape areas or indicate with notes. Add the WH basin must be 6”-9” depth; if d.g. is used, the basin must be over excavated by 2”. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff |
| 09/22/2022 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/Native Plant Preservation Section ACTIVITY NO: DP22-0091 v2 Address: 475 N Granada Ave Zoning: C-2 Existing Use: Travellers’ Accomodations Proposed Use: Multi-family TRANSMITTAL DATE: September 22, 2022 DUE DATE: September 14, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. 1. This comment was not adequately addressed – It also needs to on the grading plan - Please add a detail to show depressed landscape areas or indicate with notes. Add the WH basin must be 6”-9” depth; if d.g. is used, the basin must be over excavated by 2”. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff |
| 09/23/2022 | PSHELTO1 | COT NON-DSD | FIRE | Reqs Change | Plans shall show all new and existing fire hydrants and add a page that shows that all portions of all buildings are within 600' of a fire hydrant. Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner Tucson Fire Department |
| 09/23/2022 | NROSS1 | DESIGN PROFESSIONAL | REVIEW | Passed | |
| 09/26/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | email from: COTDSDPermits To: Ross Lamberson cc: Nick Roe REVIEW NOTICE Returned for Corrections: DP22-0091 Site/Grading - City Center Development, Hotel Tucson City Center. Redevelop existing hotel into multi-family units. 475 N GRANADA AV FEE BALANCE: $ 165.00 (2 extra review hours by Fire Dept) ONLINE PAYMENTS ** If the online amount doesn't match "Fee Balance" above, check again in a few hours ** https://www.tucsonaz.gov/pdsd/fees 1- Click on: Pay Planning & Permit Fees 2- Enter Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave this blank 4- "Continue" 5- In the Pay column - check the boxes YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on the blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter 3. UPLOAD documents to Filedrop: - Comment Response Letter (your response to REQUIRES CHANGE comments) - Plan Set (all pages, full set, even if no changes were made) - Documents requested by review staff FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) Sharon Beasley, Certified Permit Specialist City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov (for development packages, land splits, Thursday Presubmittal meetings) Email: PDSDinquiries@TucsonAz.gov (for building permits) |
| 09/26/2022 | SBEASLE1 | COT NON-DSD | PARKS & RECREATION | Approved | email from: Howard Dutt To: CDRC 09/26/2022 The revised Development Plan adequately address Tucson Parks and Recreation's previous comment. Approval is recommended. Howard Dutt, RLA Project Manager/Landscape Architect Parks and Recreation | City of Tucson Howard.Dutt@tucsonaz.gov main 520.631.2030 |