Review Date Reviewer's Name Type of Review Description Status Comments
07/09/2021 SBEASLE1 START PLANS SUBMITTED Completed
08/04/2021 STEVE SHIELDS ZONING REVIEW Approved
08/06/2021 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved Email from: Howard Dutt
To: CDRC
Fri 8/6/2021 10:57 AM

The City of Tucson Parks and Recreation Department's comments have been adequately addressed in the 2nd submittal.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks and Recreation
(520) 837-8040
08/10/2021 AWARNER1 LANDSCAPE REVIEW Approved
08/12/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: lisa bowers
Thu 8/12/2021 2:30 PM

Returned for Corrections: DP21-0116
Reviews have been completed. See details below.

DESCRIPTION: Site/Grading/Swppp - TEP Patriot Substation.

FEE BALANCE: $0 (zero) Thank you for the payment.

INCLUDE IN YOUR RESUBMITTAL
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your 3rd submittal documents according to this example: 3_Comment Response Letter, 07.01.21

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
(Select "Existing Application", then enter permit number)

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW


Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
Email for Building Permits: PDSDinquiries@TucsonAz.gov
08/12/2021 SBLOOD1 ENGINEERING REVIEW Approved 1. See previous comment 1 - Still don't see the address and phone number of the firm who prepared the report. It all should be provided on the cover sheet as per Admin Manual section 2-06.4.1
The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines.
08/12/2021 SBEASLE1 COT NON-DSD TRAFFIC Reqs Change Email from: David.Stiffey@TucsonAz.gov
To: CDRC
Thu 8/12/2021 2:14 PM

1. SVT: (My first request of the SVT was incorrect. My apologies. I did not realize that Escalante was an Arterial road) The appropriate SVT for Escalante Rd. is, the "near side" of the triangle needs to be 185 Feet and the far side needs to be, 125 Feet. Please correct this on the plan

2. New sidewalk is not needed along Escalante where there is an existing multi-use path. But new sidewalk is required along the frontage of the property along Kolb Rd. New sidewalk needs to be 6 Feet wide.

All other previous comments have been addressed. Please let me know after you resubmit documents and receive the standard "Plan Review Started" email from the permit specialist.

I will expedite this review.

David Stiffey
City of Tucson