Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: DP21-0044
Parcel: 13216061A

Address:
1701 E BENSON HY

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP21-0044
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2021 SBEASLE1 START PLANS SUBMITTED Completed
09/16/2021 STEVE SHIELDS ZONING REVIEW Reqs Change FROM: Development Services Department Zoning Review

PROJECT: Anytime Storage – 1701 E Benson Hwy
Development Package (2nd Review)
DP21-0044

TRANSMITTAL DATE: September 16, 2021

DUE DATE: September 28, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is February 18, 2022.

CONTENT REQUIREMENTS

1. This comment was not addressed. The total number of pages within the title block states “8”. COMMENT: 2-06.4.2.D – The total number of pages listed in the title block is not correct and should be 9.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. Zoning was not able to find street perimeter yard setback dimensions from the proposed building to the back of future curb as required. COMMENT: 2-06.4.9.O – Once the future curb has be clearly shown on the plan provide a street perimeter yard setback from the back of curb to the proposed building.

Additional comments:
3. COMMENT: 2-06.4.9.H.5 - Clarify of the access lanes are one-way or two-way. If one-way demonstrate one the plans how this will be regulated, i.e. signage, pavement markings, etc., if two-way the width does not meet the requirements of UDC Table 7.4.6-2.

4. COMMENT: 2-06.4.9.H.5 – Clearly demonstrate on the plan that a vehicle can turn around on site and exit on to Benson Hwy without having to back into the ROW it the gates won’t open.

5. Clarify where the office for this personal storage is located.

If you have any questions about this transmittal, please contact Steve Shields at Steve.Shields@tucsonaz.gov. My email will return an automatic response stating that I have retired but I am currently working as a contract employee and will respond to your questions regarding this review.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
09/20/2021 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Approved Email from: <Addressing@pima.gov>
To: CDRC
Fri 9/17/2021 3:14 PM

Pima County Addressing approves Anytime Storage, 2nd Submittal: DP21-0044.
Thank you

Nicholas Jordan, Addressing Specialist

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-9623
09/30/2021 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, PLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: Anytime Storage
ACTIVITY NO: DP21-0044
Address: 1701 E Benson Hwy
Zoning: C-2
Existing Use: disturbed vacant lot
Proposed Use: Personal Storage

TRANSMITTAL DATE: September 30, 2021
DUE DATE: September 28, 2021
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
1. UDC 2-10.4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.

2. Please provide all landscape calculations on the landscape plan, including required trees for the parking areas, Admin. Manual 2-10-4.2.A.2.c and landscape borders, UDC Technical Standards 2-10.4.2.f & g.

3. A Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening.

4. Modify details to show depressed landscape areas.

5. An irrigation plan is required, hand watering is not allowed. UDC 7.6.6

6. Please label the existing and future rights of way for Benson Hwy, UDC 7.6.4.C.2.a.

7. Per Admin. Manual 2-10-4.2.D, provide page/detail reference to civil drawings/details that show bike racks, walkways, and screening/retaining walls on landscape plans.

8. Provide a maintenance schedule for the landscape and irrigation for this project. UDC 2-10-4.2.A.4.

9. Identify the point of drainage off roof areas, amount of flow, and disposition of flow.

10. Ensure that trees in vehicular use areas are planted within and adjacent to parking so that they afford the greatest amount of shade in paved areas, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

11. Please add/call out soil moisture gauge/tensiometers and rain shut-off device on irrigation plans and details. UDC 4.2.A.

12. Identify water meter and POC on irrigation plan.

13. Add the following notes to the Native Plant Preservation Plan, UDC 7.7.5.5 On-site monitoring of all aspects of site clearing, grading, plant protection, preservation, salvage, and mitigation must be provided during project construction at the expense of the developer. The monitor must provide periodic progress reports to the developer outlining the status of work accomplished and any problems encountered. A copy of these reports must be submitted to the PDSD for the project file.

14. UDC 7.7.5.6. The monitor is responsible for an assessment of the condition of the site’s plants one year after the final inspection has been performed on the site. Copies of the report must be submitted to the site’s owner/developer and to PDSD.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
10/15/2021 SBLOOD1 ENGINEERING REVIEW Approved
10/27/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Erin Harris
Wed 10/27/2021 11:23 AM

Returned for Corrections: DP21-0044
DESCRIPTION: Site/Grading - Anytime Storage. 1701 E BENSON HY

Fee Balance: $0 (zero) Thank you for the payment.

REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

INCLUDE IN RESUBMITTAL
1) Comment Response Letter (your response to any Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your THIRD submittal documents according to this example: 3_Comment Response Letter

FILEDROP for Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff


Thank you.
Sharon Beasley, Building Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
10/27/2021 JPEELDA1 FIRE REVIEW Reqs Change On the East side of Building 2 you shall provide a 26' wide fire access lane and provide fire lane signs per TFD requirements.
Provide fire flow from TW showing 1,000 GPM at hydrant

Questions:
Jennifer Peel-Davis
520-837-7033
Jennifer.Peel-Davis@Tucsonaz.gov
10/27/2021 JPEELDA1 FIRE REVIEW Reqs Change Gate on access road shall be approved by TFD. Gate shall have a KNOX Key switch installed and KNOX box for entry to storage areas.
Fire Extinguishers shall be placed ever 150' not to exceed.