Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP19-0059
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/14/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 06/03/2019 | CLAURIE1 | DESIGN PROFESSIONAL | REVIEW | Denied | The project is subject to MGD review and shall be subject to special conditions per the Directors Dection Letter. The project shall be denied until the conditons of the MGD are met. |
| 06/05/2019 | SBEASLE1 | COT NON-DSD | TDOT | Reqs Change | 1. Please keep Irrigation Plan at same scale and orientation as the Landscape Plan. Please show vegetation faded back on Irrigation Plan. 2. Please show Sight Visibility Triangles on the Landscape Plan. Concern that benches with backs may be in SVTs. 3. Please label Streets on Landscape and Irrigation Plans. David Marhefka d?’-vid mär-hef’-ka Landscape Architect City of Tucson Department of Transportation (o) 520-837-6618 (m) 520-403-5074 |
| 06/06/2019 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 06/10/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | ADMINISTRATIVE MANUAL SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS 4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. Indicate Main Gate District Development case # T19SA00088 approval and any condition imposed Ensure that all Zoning and Engineering comments and concerns are addressed. Additional comments may apply. |
| 06/12/2019 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera PDSD Zoning Review Section PROJECT: Aspire Tucson 2 - Residential Use / Group Dwelling Use Development Package (2nd Review) 947 N. Park Avenue DP19-0059 - Current Zoning is C-1 will go to UC-1 utilizing the MGDO TRANSMITTAL DATE: June 12, 2019 DUE DATE: June 11, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is March 7, 2020. 1. COMMENT: Zoning has confirmed that the zoning comments from the previous have been addressed with the exception of the MGD process. However as there is still no official Directors decision available or included in the resubmittal of the documents Zoning could not verify if conditions of the MGD have been addressed and approved by Staff. Assure that the conditions of the MGD are listed on the cover sheet under General note 20 include the Case number T19SA00088 as reference in the lower right corner next to the title block of all plan sheets. Zoning can approve the DP once it is confirmed that the Design Professional or PDSD directors has approved the latest submittal and has addressed all conditions of the MGD. If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 06/12/2019 | DAVID RIVERA | ZONING HC | REVIEW | Approved | |
| 06/17/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 06/18/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE The reviews have been completed and a resubmittal is required. The fee balance is $0 (zero). Activity Number: DP19-0059 Project Description: SITE/GRADING/SWPPP - Aspire Tucson 2, 8-story student housing with parking garage, the east 168.01 feet of Lot 1 of Nelson Block. For review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.) After all corrections are made, please name your 3rd submittal documents accordingly, for example: 3_Plan_Set. Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, please include the Activity Number. 1) Comment Response Letter (lists changes made to the Plan and which reviewer comments you are responding to) 2) Complete Plan Set (all pages, full set) 3) Any other items requested by review staff After resubmittal, the plans will re-enter the standard 20-working-day review cycle. The Project Manager can be contacted at: Alexandra.Hines@TucsonAz.gov, (520) 837-6975 Thank you. Sharon Beasley, Permit Technician City of Tucson Planning and Development Services Attn: Permit Counter 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/18/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |