Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Permit Number - DP15-0091
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/20/2015 | AROMERO4 | START | PLANS SUBMITTED | Completed | |
| 08/21/2015 | BVIESTE1 | ENV SVCS | REVIEW | Approved | Patricia G. reviewed and approved ESD conditions of approval. |
| 08/21/2015 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 08/26/2015 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Julieann Arechederra GIS Cartographer Pima County Assessor's Office DATE: August 25, 2015 RE: Assessor's Review and Comments Regarding: DP15-0091 OAKMORE SIX 2nd (TENTATIVE PLAN) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor's Office requirements. _______ Plat does not meet Assessor's Office requirements. COMMENTS: NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 08/26/2015 | FDILLON1 | DESIGN PROFESSIONAL | REVIEW | Denied | Requires Architectural Variation Plan (AVP) per UDC Sec. 8.7.3. / Administrative Maunual Section 2-06.5.3.E. |
| 08/26/2015 | BVIESTE1 | PIMA COUNTY | ADDRESSING | Reqs Change | 201 N. STONE AV, 1ST FL TUCSON, AZ 85701-1207 MICHELENE NOWAKADDRESSING REVIEW TO: CITY PLANNING FROM: MICHELENE NOWAK, ADDRESSING REVIEW SUBJECT: OAKMORE SIX LOTS 1-68 COMMON AREAS A1-A-3, B1-B4/TENTATIVE PLAT-2nd REVIEW DATE: AUGUST 26, 2015 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1.Street labeled “River Crest Drive” (public street) cannot be used due to duplication. To avoid duplication of street names, email possible name choices to Addressing for review: addressing@pima.gov 2.Correct Title Block on all Sheets to read:Oakmore Six Lots 1-68 and Common Areas A1-A3, B1-B4 being a re-subdivision of a portion of Block A of Oakmore at Midvale recorded in Book 47 of M&P at Pg 15; Book 48 of M&P at Pg 99 and Book 51 of M&P at Pg 50, a portion of the NE Quarter of Section 3, T-15S, R-13-E, G&SRM, Pima County, Arizona |
| 09/02/2015 | JASON GREEN | ENGINEERING | REVIEW | Approv-Cond | DATE: September 02, 2015 DUE DATE: September 18, 2015 SUBJECT: Oakmore Six Development Plan Package- 2nd Engineering Review TO: KB Home, Attn: Mathew Cawley LOCATION: 1425 W Irvington Rd REVIEWERS: Jason Green, CFM ACTIVITY: DP15-0091 SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Development Package, Drainage Report (JE Fuller Hydrology & Geomorphology, Inc., 05JUN15), Geotechnical Report (Wright Engineers, 27MAY15), Stormwater Pollution Prevention Plan (Trinitygreen, 31JUL15), Amended CC&Rs (21JAN04), and Temporary Private Drainage Easement (Docket 10316 Page 1655). Engineering Division recommends conditional approval of the Development Plan Package at this time. The following items need to be addressed at submittal: DEVELOPMENT PACKAGE: 1) AM Sec.2-06.4.9.N.3: Prior approval from TDOT and Real Property will be required to install the proposed pipe through City property. A maintenance and construction easement will be required. It is acknowledged that KB Homes is in the process to acquire the easement through TDOT and Real Property however this will be required prior to DP approval and the start of grading construction. 2) AM Sec.2-06.5.3.F: Provide 3 copies of the CC&Rs regarding the HOA's responsibility for ownership and maintenance of commonly owned property. It is acknowledged that the HOA is the responsible party for maintenance of the Common Areas per the CC&Rs provided however the CC&Rs must be amended to reflect the new proposed subdivision and specifically call out the lots and common areas as will be recorded under the new Final Plat. This item is a conditional item and can be addressed at the Final Plat submittal. GENERAL COMMENTS: Please provide the supplemental information requested above for Development Package review and approval. For expedite purposes the Development Package can be reviewed over the counter (PDSD Engineering Division comment only) for stamp approval once the supplemental information is provided. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 09/03/2015 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: DP15-0091 1425 W Irvington Road FLD Tentative Plat - Lots 1-68 and Common Areas A1 - A3 and B1 - B3 TRANSMITTAL DATE: September 3, 2015 DUE DATE: September 18, 2015 COMMENTS: Conditionally approved. 1. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is June 10. 2015. 1. Follow up to previous comment 13: The location of keynote 13 on sheet C1-3 could not be verified. If the keynote is not applicable on this sheet remove the keynote. 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks. 13. COMMENT: Clarify if the three (3) turn-around areas in Common Area A-1 will remain or are they to be removed? If they are to remain will the turn -around areas be re-recorded as part of the new plat and made permanent? Clarify. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 09/18/2015 | JANE DUARTE | COT NON-DSD | PARKS & RECREATION | Approved | Approved. Howard B. Dutt, RLA Landscape Architect Tucson Parks & Recreation (520) 837-8040 Howard.Dutt@tucsonaz.gov >>> DSD_CDRC 8/21/2015 2:34 PM >>> Dear Reviewers: This is an electronic distribution for a CDRC Tentative Plat review. If you normally receive paper copies of the review documents, you will receive them soon. The applicable case numbers are: CDRC Development Plan: DP15-0091 Existing and Proposed Zoning: Proposed Use: Residential subdivisionDue Date: September 17, 2015 |
| 09/18/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Revise Note 4 on sheet C2.1 to delete the words, "(and/or downstream)". [Initial comment: Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor (e.g. lots 18, 19, 20, 30, 31, and 32). Floors discharging from above that reference point shall not discharge through the backwater valve. Provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.] |
| 09/22/2015 | BVIESTE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) 4 Rolled sets of the plan 2) A disk containing all items submitted 3) All items requested by review staff 4) All items needed to approve this plan |
| 09/22/2015 | BVIESTE1 | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: OAKMORE SIX – TENTATIVE PLAT D15-0091 Tucson Electric Power Co. (TEP) has reviewed and approves the tentative plat submitted for review on August 21, 2015. In order for an electrical design to be completed, please provide a copy of the Approved Tentative Plat and the subdivision AutoCAD file to mburke@tep.com. Easements for TEP facilities must be shown on the Final Plat before TEP can approve the plat. If you have any questions, please feel free to contact me at 917-8744. Mary Burke Right of Way Agent Tucson Electric Power Co. Mail Stop HQE613 PO Box 711, Tucson, AZ 85702 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/24/2015 | KROBLES1 | OUT TO CUSTOMER | Completed |