Permit Number: TD-DEV-1223-00472
Parcel: 124130260

Address:
502 S FREMONT AV

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.4

Permit Number - TD-DEV-1223-00472
Review Name: DEVELOPMENT PACKAGE NEW v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/05/2025 Commercial Plumbing APPROVED
02/20/2025 Site Zoning APPROVED
03/14/2025 CDRC Post Review Express PENDING ASSIGNMENT
03/14/2025 Site Engineering REQUIRES RESUBMIT 1. ADA Parking required, since only one ADA space is required, it must be van capable.
2. Interior pedestrian circulation required to west door, not west property line.
3. Driveway apron must be ADA compliant and concrete per PAG standard.
4. Detail apparent swale in rear of building.
5. ADA access required from parking to pedestrian circulation.
6. Spot elevations shown on sheet 7 of 8 indicate that pedestrian cross slope exceeds 2% - verify elevations.
7. Clarify scupper locations with a keynote.
8. Clarify apparent splash blocks at roof drains.
Joshua Garcia
joshua.garcia@tucsonaz.gov
03/14/2025 Site Landscape REQUIRES RESUBMIT CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: DEVELOPMENT PACKAGE FOR MULTIFAMILY TRIPLEX BUILDING
ACTIVITY NO: TD-DEV-1223-00472
ADDRESS: 502 S FREMONT AV
ZONING: R-3 RESIDENCE ZONE
LAND USE: MULTIFAMILY
REVIEW #2

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape/NPPO Section review comments have been addressed.

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. Add a bold general note to the rainwater harvesting plan that refers to the civil grading plan for all drainage and basin construction including slopes, spot elevations, contouring, curb cuts, downspouts, splash pads, scuppers, etc.

2. Prior to Site Landscape Development Package approval, all Site Engineering comments must be addressed with regard to the information needed for proper grading, drainage, site layout and constructability.

3. South of the parking area the planting area is only 2.5 feet in width. UDC requires a minimum of 4 feet in width. Adjust this area to be a minimum of 4 feet in width for tree and shrub viability.

4. The west parking area planter island is very narrow as well (2.5 feet). Adjust this area to be 4 feet in width. This will require an adjustment of the parking stalls towards the eastern planting area.

5. Include the correspondence emails or letters that have granted the approval of the 6’ setback on the south property line.

6. Add a general note: Any discrepancies in plant material between the plan and the planting legend, that the quantities drawn on the plan shall take precedence. Or wording to this effect.

7. Separate valves and irrigation lines are required for trees and shrubs. Graphically show the separate irrigation lines and valves on the irrigation plan.

Thank you.
Chad Keller, RLA
Landscape Architect