Permit Review Detail
Review Status: In Review
Review Details: DEVELOPMENT PACKAGE NEW REVISION v.1
Permit Number - TD-DEV-0825-00212
Review Name: DEVELOPMENT PACKAGE NEW REVISION v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | Commercial Plumbing Standard | PENDING ASSIGNMENT | |||
| N/A | Entitlements Standard | PENDING ASSIGNMENT | |||
| N/A | External Reviewers - COT Parks & Recreation Standard | PENDING ASSIGNMENT | |||
| N/A | External Reviewers - Tucson Electric Power (TEP) Standard | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| N/A | NPPO Standard | PENDING ASSIGNMENT | |||
| N/A | ROW Engineering Review Standard | PENDING ASSIGNMENT | |||
| N/A | Site Landscape Standard | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 04/01/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0825-00212 (1st Review) Project: PHASE III of JTED Bridges Location: 751 E TUCSON MARKETPLACE BL Review Date: 4/1/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Related Cases: *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. * City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. For the ADA parking on the North side of the “Future 2-story building #4”, It appears there are ramps missing to connect the access lanes to the actual sidewalk, as keynote #10 calls out 6-inch curb. After reviewing the grading plan it appears both the sidewalk and pavement are intended to be flush - revise the site plan line work and keynote call-out accordingly. 2. Provide trash enclosure details in compliance with TSM 8-01.5.0 It’s encouraged to use the figures presented in TSM 8-01.9.0 for minimum basis for details for the Dumpster layout shown. 3. Revise trash enclosure detail and grading sheet/plan (Sheet 9) sheets to show all the trash enclosures ramps slopes being 2% away from enclosure as well as the enclosure slabs sloping 1% to the gate. TSM 8-1.0.0 If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 03/24/2026 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 03/27/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added Addressing, Parks,TAA, ADOT, TEP, PAG, USPS, and SWG to the workflow. Review request email sent to Addressing, Parks, TAA, ADOT, and TEP. FYI email sent to PAG, USPS, SWG. | ||
| 04/06/2026 | External Reviewers - Arizona Department of Transportation (ADOT) Standard | REVIEW COMPLETED | ADOT has no comments. Thanks, Rick Freije |
||
| 03/27/2026 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 04/02/2026 | External Reviewers - Pima County Addressing Standard | REVIEW COMPLETED | Good afternoon, Pima County Addressing approves TD-DEV-0825-00212. The correct address for the new building is 3300 S Park AV Building 3. Thank you |
||
| 03/27/2026 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 03/31/2026 | External Reviewers - Tucson Airport Authority Standard | REVIEW COMPLETED | March 29, 2026 Planning and Development Services City of Tucson 201 North Stone Avenue Tucson, AZ. 85701 RE: TD-DEV-0825-00212, 2nd Submittal, New connex containers (11) for JTED Construction Technologies, 751 E Tucson Marketplace Blvd, Tucson AZ 85713, Received March 27, 2026 To whom this may concern, Thank you for the opportunity to comment on TD-DEV-0825-00212, 1st Submittal, a development plan for new storage containers at 751 East Tucson Marketplace Blvd. This development is located in the S.W of the quarter of the N.W. quarter of Section 30, Township 14S, Range 14E, of the Gila and Salt River Meridian. The development site occupies parcel numbers 132-13-104A and 132-13-104B, covers approximately 7.35 ± acres, and is zoned as Planned Area Development 15 Zone (PAD-15). The nearest major roadway intersection is South Park Avenue and East Tucson Marketplace Boulevard, approximately 1,000 feet to the west of the subject development. This site does lie within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport Authority approves the 1st submittal of this project and is not requiring a resubmittal of this project. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520- 573-4811. Respectfully, Scott Robidoux, C.M. Manager of Planning cc file |
||
| 03/27/2026 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 03/25/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | Review all Activity Notes - Complete Phase III Revision - Fees & Reviewers will need to be updated | ||
| 03/27/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED |