Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0725-00187
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/23/2025 | ROW Engineering Review Standard | REQUIRES RESUBMIT | |||
| 12/23/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TD-DEV-0725-00187 Location: 780 W EL PUENTE LN Review Date: 12/23/2025 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Comments: 1. As this development package TD-DEV-0725-00187 has not been fully approved and issued, every change made until full first approval does not need to be revision clouded. Revise plans to remove all revision clouding from the plan set. 2. Provide the general note “The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall.” Administrative Manual 2-06.4.7.B.1 3. Provide the general note “Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this site plan.” AM 2-06.4.7.B.3 4. Provide the general note “No structure or vegetation shall be located or maintained so as to interfere with the sight visibility triangles in accordance with Section 10-01.5.0, Sight Visibility, of the Technical Standards Manual.” AM 2-06.4.7.C.2 5. Provide Sight visibility triangles for the site entrance along Country club in compliance with TSM 10-01.5.0 It should be noted that Benson HY is designated as Arterial RD for reference when reviewing the SVT tables. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 12/23/2025 | Site Landscape Standard | REQUIRES RESUBMIT | |||
| 12/23/2025 | Site Zoning Standard | REQUIRES RESUBMIT |