Review Date Reviewer's Name Type of Review Description Status Comments
06/07/2024 PDSD Application Completeness REQUIRES RESUBMIT Resubmit with a complete Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804. Identify live and dead loads.

Show the location of the damage and repairs to be made. Provide a detail showing the proposed repairs to the 2x12 beam. Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. Provide framing details to show attachment of new roof structures to existing structure.